HT9023
EN - 40
23. While measuring P-Q-S power or PF-DPF, press
F3
(
Fnc
) to
open the drop-down menu shown on the screen aside. At
each subsequent pressure of
F3
, the cursor will scroll
through the available items, as follows:
Max
: it constantly displays the maximum value of the
measured parameter
Min
: it constantly displays the minimum value of the
measured parameter
RST
: (RESET) it deletes all stored Max, Min values and
re-start with a new measure
Start Log
start a new recording with integration period
set in § 4.4.3
Snapshot
it allows the saving of an instant sampling
whose reference is visible in the "Memory REC" section
of the instrument (see § 4.4.5)
Download
it allows to perform the WiFi data transfer to
PC of saved data via TopView software or to mobile
devices via APP HTAnalysis (see § 6.1)
Esc
: it goes back to a normal measuring mode
Mod Par
Fnc
OK
A C 5 0 . 0 H z
2 1 . 4 7
k W
7 . 6 8
k V a r i
2 2 . 9 0
k V A
1 P
17/01 – 18:34:23
24. Pressing
F4
(
OK
), the selected item is confirmed. Nearby, an
example of power measurement with active Max function.
The display shows the active function.
Mod Par Fnc Zro
A C 5 0 . 0 H z
M a x
8 0 . 0
V
2 0 . 0
A
1 P
17/01 – 18:34:23
25. For the use of HOLD and backlight features see § 4.4
Max
Min
RST
Start Log
Snapshot
Download
Esc