background image

版本号

密级

内部

A1

会签

阶段
标记

S

RFL-A1000D~2000D

光纤输出半导体激光器英文说明书

RFL-A1000D~2000D·JS02

部 门

半导体激光器技术研究部

编 写

曾诚

20201222

校 对

李辉

20201225

审 核

刘超

20201228

标 审

李其军 20201231

批 准

胡慧璇 20201231

无锡锐科光纤激光技术有限责任公司

王志源

黄文娟

旧底图登记号

/

底图登记号

/

 

 

 

 

 

 

 

武汉锐科

 

 

Summary of Contents for RFL-A1000D

Page 1: ...A1 S RFL A1000D 2000D RFL A1000D 2000D JS02 20201222 20201225 20201228 20201231 20201231...

Page 2: ...Fiber Delivered Direct Diode Lasers User Guide RFL A1000D 2000D...

Page 3: ...es 6 2 Product Description 6 2 1 Features 6 2 2 Model Configuration 6 2 3 Package Contents 7 2 4 Unpacking and Inspection 7 2 5 Operation Environment 8 2 6 Specifications 9 2 7 Properties of Products...

Page 4: ...ng Process 27 4 6 Selection of Control Mode 27 4 7 Pilot Light to Control 35 4 8 Steps of Shutting Down 36 5 Alarms and Solutions 36 5 1 Alarms Display 36 5 2 Alarm Solutions 36 6 Warranty Return and...

Page 5: ...7247 1 clause 9 this type of laser is a class 4 laser instrument The product emits laser radiation with a wavelength of 915nm or around 915nm and the optical power radiated by the output head is great...

Page 6: ...op View and Back View Figure 1 shows the product safety labels and its location These safety signs include safety warnings laser output head warnings product nameplates etc The safety identification d...

Page 7: ...ough a lens with an anti reflection coating make sure that the lens is of good quality and clean 1 5 Electrical Safety a Make sure your product is grounded through the PE line of the AC power cord The...

Page 8: ...used and warranty will be void 2 Product Description 2 1 Features Compared with traditional lasers Raycus CW fiber diode laser has higher efficiency electric optical conversion lower power consumption...

Page 9: ...indicates iHQB interface B indicates SMA905 interface C indicates D80 interface 7 Cooling method W indicates water cooling T indicates TEC air cooling A indicates air cooling 2 3 Package Contents Ple...

Page 10: ...head is precise optic instrument any vibration or impact to the output head and twist or excessive bend to the cable will damage the instrument 2 5 Operation Environment The basic operation conditions...

Page 11: ...requirements of the laser Therefore in the corresponding environment the water temperature of the laser can only be set in the blue region of the dew point comparison table so this method has certain...

Page 12: ...peration of the water cooling machine under the shutdown state of the laser h Failure to follow the specified instructions may result in the loss of laser power and such loss will not be covered by th...

Page 13: ...e Electrical Parameters Power Supply single phase 220VAC 10 50 60Hz three phase 380VAC 10 50 60Hz Control Mode RS 232 AD Other Parameters Dimensions W H D mm 485 133 584 485 133 661 Weight kg 36 38 40...

Page 14: ...Wuxi Raycus Fiber Laser Technologies Co Ltd User Guide of Raycus 1000W 2000W laser 12 Figure 3 1 Top View of 1000w Laser unit mm Figure 3 2 Top View of 1500w Laser and 2000w Laser unit mm...

Page 15: ...e must be ensured to be connected to the two copper rings of the output head otherwise an alarm will be generated It is strictly prohibited to disassemble the output head by personnel not approved by...

Page 16: ...from the product and then both the inlet and outlet must be blocked with the nuts we provide Failure to do so may lead to permanent equipment damage 3 When the customer is empting the cooling water of...

Page 17: ...output head process please make sure that the surrounding environment is clean otherwise it may pollute the output head do not use fans which actually may bring more dust All the cables can only be co...

Page 18: ...software and the relevant manual http www raycuslaser com index php index show tid 53 html 4 1 Front and Rear Panel Figure 5 Front View LASER Laser emission indicator red led illuminates when laser em...

Page 19: ...signal should be able to apply current over 10mA and the voltage should be 24V WATER IN OUT Water pipe connectors the inlet and outlet for cooling water to flow in and return AC INPUT 1000W and 1500W...

Page 20: ...ce Each pin is defined as shown in Table 8 below Table 8 SERVICE definition PIN Name Function Remark 1 PowerA Remote switch Passive contact Can t be connected to external voltage or ground Short circu...

Page 21: ...the connector as in Figure 8 Figure 8 Modulation Input Raycus provide MOD Cable as shown in figure 9 Figure 9 MOD Cable The Cable for Modulation Signal The modulation signal cable core is positive 24V...

Page 22: ...MOD Input External modulation signal 24V 10mA or above The internal circuit of the modulation signal is shown in figure 10 Figure 10 The Internal Circuit of The Modulation Signal 4 3 3 Control Interfa...

Page 23: ...NO 0V 9 EX_GND Reference6 7 8 20 24GND 0V 15 LASER_EN_ON Short circuit the pin 15 and 16 to enable laser disconnect these to shut down laser 16 LASER_EN_VCC 17 REM_ON Short circuit the pin 17 and 18...

Page 24: ...is in accordance with the requirements Over voltage and voltage ripple may damage the product Make sure that the analog voltage signal does not exceed 10V otherwise the product may be damaged Figure...

Page 25: ...cription 2 RX 3 TX 5 GND Others NC 4 3 5 TCP IP Interface Configuration The default IP address of this product is 192 168 0 10 only supports UDP communication The laser listens for connection on port...

Page 26: ...er the verification is passed read or set the new laser IP address c If you use the Raycus PC software to control the laser you need to find the folder where the PC software is located open the laser...

Page 27: ...Wuxi Raycus Fiber Laser Technologies Co Ltd User Guide of Raycus 1000W 2000W laser 25 Figure 15 The Steps of Ethernet Connection...

Page 28: ...rnally AD mode is to set up parameters MOD Analog Quantity and control laser enable signal externally Internal control mode is to set up parameters and control laser enable signal internally Each cont...

Page 29: ...r Alarm Laser alarm Control Interface Laser EN Control Interface s the pin LASER ON is high level Interlock Control Interface s the InterLock is on Emission The laser is emitting laser REM The laser i...

Page 30: ...er Control Set parameters Laser Power Frequency Duty Ratio Set After Setting parameter Need to click set Emission on Pressing the button the laser is emitting laser button is unavailable the laser is...

Page 31: ...e internal circuit initialization phase is complete e Setting the laser power by upper computer software f The MOD interface provides modulating signal for the laser g Enable the laser through one of...

Page 32: ...Wuxi Raycus Fiber Laser Technologies Co Ltd User Guide of Raycus 1000W 2000W laser 30 Figure 19 Control Sequence Diagram of PLUSE Pattern in External Control RS232 Mode...

Page 33: ...of Raycus 1000W 2000W laser 31 4 6 4 Wiring in External Control AD mode Figure 20 Wiring In External Control AD Mode 4 6 5 The Operation Procedure of External AD mode a Short circuit DB25 control int...

Page 34: ...d e The power of the laser is controlled by the voltage obtained by PIN 22 25 of the DB25 interface connector f The external MOD interface provides modulating signal for the laser g Enable the laser t...

Page 35: ...Disconnect DB25 control interface s PIN17 and PIN18 Select internal control mode b Connect to AC power and the Power indicator on the front panel light on c Waiting for 10s until the internal main co...

Page 36: ...trol Sequence Diagram of CW Mod in Internal Control Mode Figure 24 Control Sequence Diagram of Pulse Mod in Internal Control Mode 4 7 Pilot Light to Control Connect to AC power Both POWER green indica...

Page 37: ...out alarm information If any alarm occurs except for Interlock alarm when the laser is running the homepage will display the alarm that occurs and the ALARM light yellow on the front panel of the las...

Page 38: ...e laser if this error continues to occur please contact Raycus T1 T2 T3 T4 Alarm Instruction Low temperature high temperature alarm of the laser The sensor in the laser detects an abnormal temperature...

Page 39: ...disassembling misuse accident modification unsuitable physical or operating environment improper maintenance damages caused by those who are not from Raycus due to excessive use or not following the i...

Page 40: ...table container d If any damage happened to the product please notify the carrier in document immediately We reserve the right to make changes in design or constructions of any of our products at any...

Reviews: