HT9022
EN - 13
5.2.3. Log
By selecting “
Log
”, the screen to the side will appear.
Press keys
F2
,
F3
(
T
,
S
) to change the duration of the
integration period. It will take the following values:
1, 5, 10, 30, 60, 120, 300, 600 or 900 seconds.
Press key
F4
(
OK
) to save the changes made and go back to
the previous screen (see par.5.2).
▼
▲
OK
I n t . P e r i o d :
0 0 1
s
19/01-17:00:00
5.2.4. InRush
By selecting “
InRush
”, the screen to the side will appear.
Press key
F1
(
Sel
) to move the cursor and keys
F2
,
F3
(
T
,
S
)
to change the selected item.
Press key
F4
(
OK
) to save the changes made and go back to
the previous screen (see par.5.2).
•
Thresh
: threshold value beyond which the inrush current
event is detected and recorded by the instrument. The
current value may be set between 5A and 900A in steps of
1A.
Sel
▼
▲
OK
T h r e s :
0 8 0
W i n d o w : 1 / 1
M o d e : F i x
19/01-17:00:00
•
Window
: the value of the inrush current measuring window. The following values are
available:
¾
1/1
: sampling occurs every half-period;
¾
1/2
: sampling occurs one every two half-periods;
¾
1/4
: sampling occurs one every four half-periods;
•
Mode
: the inrush current measuring mode. Following modes are available:
¾
Fix;
¾
Var.
For details about the measurement of Inrush Currents see par. 5.8.2.
5.2.5. Continuity
By selecting “
Continuity
”, the screen to the side will appear.
Press keys
F2
,
F3
(
T
,
S
) to change the setting of the resistance
limit value below which the buzzer will sound. It may be set
between 1
Ω
and 150
Ω
in steps of 1
Ω
.
Press key
F4
(
OK
) to save the changes made and go back to
the previous screen (see par.5.2).
Sel
▼
▲
OK
R e s L i m :
0 1 0
Ω
19/01-17:00:00