background image

   HTA105 

 

 

 

 

EN - 15

8. ASSISTANCE 

8.1. WARRANTY 

CONDITIONS 

This instrument is warranted against any material or manufacturing defect, in compliance 
with the general sales conditions. During the warranty period, defective parts may be 
replaced. However, the manufacturer reserves the right to repair or replace the product. 
Should the instrument be returned to the After-sales Service or to a Dealer, transport will 
be at the Customer's charge. However, shipment will be agreed in advance. A report will 
always be enclosed to a shipment, stating the reasons for the product's return. Only use 
original packaging for shipment; any damage due to the use of non-original packaging 
material will be charged to the Customer. The manufacturer declines any responsibility for 
injury to people or damage to property. 
 
The warranty shall not apply in the following cases: 
 

  Repair and/or replacement of accessories and batteries (not covered by warranty) 

  Repairs that may become necessary as a consequence of an incorrect use of the 

instrument or due to its use together with non-compatible appliances. 

  Repairs that may become necessary as a consequence of improper packaging. 

  Repairs which may become necessary as a consequence of interventions performed 

by unauthorized personnel. 

  Modifications to the instrument performed without the manufacturer's explicit 

authorization. 

  Use not provided for in the instrument's specifications or in the instruction manual. 

 
The content of this manual cannot be reproduced in any form without the manufacturer's 
authorization. 
 

Our products are patented and our trademarks are registered. The manufacturer 
reserves the right to make changes in the specifications and prices if this is due to 
improvements in technology.

 

 

8.2. ASSISTANCE 

If the instrument does not operate properly, before contacting the After-sales Service, 
please check the conditions of the battery and replace it, if necessary. Should the 
instrument still operate improperly, check that the product is operated according to the 
instructions given in this manual. Should the instrument be returned to the After-sales 
Service or to a Dealer, transport will be at the Customer's charge. However, shipment will 
be agreed in advance. A report will always be enclosed to a shipment, stating the reasons 
for the product's return. Only use original packaging for shipment; any damage due to the 
use of non-original packaging material will be charged to the Customer. 
 

Содержание HTA105

Страница 1: ...Copyright HT ITALIA 2018 Version EN 1 00 19 03 2018 ENGLISH User manual...

Страница 2: ...4 3 8 Key MAXMIN 5 4 3 9 Key MEAN 5 4 4 Instrument settings 6 5 OPERATING INSTRUCTIONS 8 5 1 Measurement of air speed and temperature 8 5 2 Measuring volumetric flow rate and air humidity 9 5 3 Calcu...

Страница 3: ...ng observe the instructions given in this manual improper use could damage the instrument or its components 1 1 PRELIMINARY INSTRUCTIONS We recommend following the normal safety rules devised to prote...

Страница 4: ...ked from an electric as well as mechanical point of view All possible precautions have been taken so that the instrument is delivered undamaged However we recommend generally checking the instrument i...

Страница 5: ...CRIPTION OF THE DISPLAY CAPTION 1 Speed measurement icon 2 Active Settings 3 Active Data HOLD 4 Indication of minutes seconds 5 Indication of active Auto Power OFF 6 Low battery symbol 7 Main display...

Страница 6: ...allows selecting the measuring unit of air temperature shown on the secondary display between the options C Celsius and F Fahrenheit selecting the measuring unit of air volumetric flow rate between t...

Страница 7: ...n the display 4 Press keys UNIT or UNIT to select the desired measuring unit among the options in2 m2 or ft2 5 Press key ENT to confirm The screen in Fig 4 left side is shown on the display Fig 4 Sett...

Страница 8: ...PA mbar not measured by the instrument is displayed Fig 6 Setting of atmospheric pressure value CAUTION The atmospheric pressure value is important for the necessary compensation in order to obtain ac...

Страница 9: ...y UNIT to set the measuring unit of air speed see 4 3 5 and key UNIT to set the measuring unit of air temperature see 4 3 6 on the secondary display after press key FLOW TEMP 4 Let the protection slid...

Страница 10: ...shown on the display 6 Press key UNIT to select measuring unit CMM or CFM on the secondary display see 4 3 6 7 Let the protection slide see Fig 1 part 15 until the sensors are covered and check that...

Страница 11: ...to be carried out with the same procedure as for air speed 5 Press key MEAN Symbols and Mean are shown in the bottom part of the display while the number of the measuring spots are show on the main d...

Страница 12: ...as for air speed 5 Press and hold 2s key MEAN Symbols Mean and and air speed are shown respectively in the bottom part of the display and on the secondary display while symbols 0000 and mm ss timer ex...

Страница 13: ...ation make sure you have removed the probe from the input terminal When symbol is shown on the display air speed indication is flashing and in these conditions the measured value does not comply with...

Страница 14: ...122 0 F 0 1 F 1 8 F Measurement of air relative humidity Range Resolution Accuracy 0 RH 100 RH 0 1 RH 5 RH 7 1 1 General characteristics Mechanical characteristics Size L x W x H 190 x 65 x 45mm 7 x 3...

Страница 15: ...e humidity 80 RH Storage temperature 10 C 60 C 14 F 140 F Storage humidity 80 RH Max operating altitude 2000m 6562ft This instrument complies with European Directive EMC 2014 30 EU This instrument sat...

Страница 16: ...consequence of improper packaging Repairs which may become necessary as a consequence of interventions performed by unauthorized personnel Modifications to the instrument performed without the manufa...