Page
8
GETTING STARTED
GETTING STARTED
The MI TOWER and MI TOWER+
requires only one person to assemble and dismantle it.
The MI TOWER STAIRS
requires two persons.
Your
tower
is supplied with uniform 1m high rung frames which can be used at any
stage of the assembly. During erection, the frames may be connected together to create 2m high frames
which makes assembly both quicker and easier.
STABILISERS POSITIONING
Stabilisers are supplied and must be used for all
tower
heights.
For maximum effect arrange the stabilisers by positioning at an angle of 45 degrees to give a footprint as close
to square as possible, as shown in fig. 1.
If the tower is to be positioned against a wall, the stabiliser footprint can be altered as shown in fig. 2 but only
where the heights of the wall is a minimum of two thirds the height of the top working platform.
Ensure that all four stabilisers’ feet are in contact with the ground and that the ground can support the weight
of the tower and stabilisers.
MOVING YOUR
TOWER
When your
tower
needs to be moved a small distance to enable you to continue your task, this can be
achieved provided the stabilisers can remain in pattern and all tools, materials and personnel are removed
from the tower.
You will need to raise the stabilisers so that they are no more than 25mm above the floor and properly locked.
However, if the stabilisers have to be repositioned and this reduces the footprint, your MiTOWER must be
reduced in height to 2m.
You must only move
the tower
by manual effort at a slow pace and only after fully assessing the risk. Once
moved, always check
the tower
before using.
If
the tower
is to be moved to a new location, a new level or over rough terrain, it must be fully dismantled and
rebuilt at the new location.