Sample SDI-12 comms session:
(commands sent to the AD375MA are in “
red
” and the AD375MA replies are in “black”)
(Parameter X17 is set to 0 when unit is supplied from the factory – BattV measure is OFF)
?!
0
(What address are you ? reply indicating 0)
0I!
013HydrServAD375M5.3A-001
(ID command – product ID reply)
0M!
00001
(Measure command – reply indicating 1 measurement ready in 0 secs)
0D0!
0+0001.234
(Data command – reply indicating water level is 1.234m)
0R0!
0+0001.234
(Contin Measure – same result as an M and D command combination)
(Compliance with SDI-12 Spec V1.3 (implementing CRC ) occurs in AD375MA S/W Rev 5.0 and higher)
0MC!
00001
(Measure command with CRC request – reply 1 meas ready in 0 secs)
0D0!
0+0001.028Kb| (Data command – reply indicating water level is 1.028m with a
CRC of “Kb|” according to the SDI-12 specification)
0RC0!
0+0001.028Kb| (Continuous measure with a CRC request – same result as an
M and D command combination with a CRC of “Kb|”)
0X17+1!
00001
(Set X17 parameter to 1 – sets BattV measure to ON
(X17 is implemented in S/W Rev 5.3 and higher)
0M!
00003
(Measure command – reply indicating 3 measurements ready in 0 secs)
0D0!
0+0001.234+3.6+12.8
(Data command – reply is :
)
(water level, lithium battV and external battV )
( +1.234m +3.6V +12.8V )
0R0!
0+0001.234+3.6+12.8
(Contin Measure – same result as an M and D command)
Содержание AD375MA
Страница 7: ...HyQuest Solutions Pty Ltd Model AD375MA Copyright Page 7 Issue 3 July 2017 ...
Страница 9: ...HyQuest Solutions Pty Ltd Model AD375MA Copyright Page 9 Issue 3 July 2017 ...
Страница 10: ...HyQuest Solutions Pty Ltd Model AD375MA Copyright Page 10 Issue 3 July 2017 160 246 246 94 150 ...
Страница 11: ...HyQuest Solutions Pty Ltd Model AD375MA Copyright Page 11 Issue 3 July 2017 ...