HyQuest Solutions Pty. Ltd.
Model AD375MA
© Copyright
Page 12
Issue 3 July, 2017
3.
Maintenance
The AD375MA (as well as AD37.5MA, AD150MA and AD100MA) Shaft Encoders require
no maintenance, however all connected mechanical equipment should be periodically
checked for cleanliness and ease of operation.
Internal 3.6V Lithium AA batteries should be replaced every 2 years.
Internal Batteries Replacement Instruction:
•
Loosen the 4 screws on the enclosure lid
•
Remove the lid
•
Cut restraining strap
•
Remove and replace batteries one at a time (ensuring polarity is correct) to ensure
processor is not interrupted (use a 3.6v Lithium battery -AA package)
•
Fit a new restraining strap (150mm cable tie)
•
Replace enclosure lid ensuring a proper fit
•
Tighten the 4 screws