TLC-FCR-T Operation 

 

 

Operation with OPR-1 

24 

ºC

AUTO 

CLOCK 
0:00 

 

h

 

j

 

11 

l

 

k

 

i

 

SLEEP 

MINUTE 

HOUR 

TIMER 

BOOST 

MODE 

g

 

f

 

e

 

d

 

c

 

The deluxe version may be alternatively operated with an infrared 
remote controller.  
 
1.

 

Mode indication, Auto, Dry, Cool, Fan, Heat 

2.

 

2-digit display of setpoint 

3.

 

Fan indication 

4.

 

4-digit display of current time or delayed switching time 

5.

 

Standby button: Toggles Standby/Comfort mode 

6.

 

Mode button, changes operation modes 

7.

 

UP/DOWN Button: Set point adjustment buttons 

8.

 

FAN Button: Changes fan speed, low – medium – high or Auto 

9.

 

Boost button, activates full output for 5 Minutes 

10.

 

Time related buttons: Timer, Hour, Minute 

11.

 

POWER Button: Operation mode ON - OFF 

 

Switching ON 
The unit is switched on by pressing the POWER button. It will start up in comfort mode. 

Changing between COMFORT and STANDBY 
Pressing the SLEEP button toggles between STANDBY and COMFORT modes.  

Switching OFF 
Pressing the POWER while the unit is on, will switch the unit off. The current time will be displayed in the LCD of OPR-1.  

Changing of set points 
Only the set points for the temperature loop may be changed. Set point range is 15 to 30 °C. 

Changing of fan speeds 
Repeatedly pressing the fan speed button steps through low, medium, high and automatic fan speeds. Automatic fan 
speed will not be activated in FAN ONLY mode.  

Boost 
Pressing the boost button activates a 5 minute boost. The output will be fully opened for the period of 5 minutes 
independent of demand. This may be used to change stale air during a meeting break or when entering the room.  

Clock settings 
The remote controller contains a daytime clock. In order to set the clock, press HOUR and MINUTE button together 
until the clock starts blinking. Then set the correct time with the HOUR and MINUTE buttons. Confirm by pressing the 
TIMER button.  

Delayed switching 
The unit may be delayed switched on or off using the timer button. Pressing the timer button once will display Timer 
ON if currently in OFF mode or TIMER OFF if currently in ON mode. Set the time when the unit is supposed to switch 
on or off using the HOUR and MINUTE keys.  

Mode changes 
Repeatedly pressing the mode button may activate the following operation modes: HEAT, COOL and FAN ONLY. The 
mode change may be disabled using the UP parameters.  

TLC-FCR-T, V2.0 22.03.2007                  HRW Limited              Subject to alteration Without Notice 

Page 6 

Содержание TLC-FCR-T

Страница 1: ...for a spring return valve General Description The TLC FCR T is a stand alone electronic fan coil controller with one control loop The TLC FCR T features 1 internal NTC temperature sensor one open contact or external NTC temperature input and four binary outputs Relays A detailed parameterization is possible with the use of a simple configuration routine The TLC FCR T can be configured using the st...

Страница 2: ... of fire proof ABS plastic 3 The front part made of white fire proof ABS plastic Installation 1 Arrange the wires to be connected and cut them to equal length 2 Connect them to the terminals of the power case according to wiring diagram 3 Clip the power case to the mounting plate pull the connection cable through the large central opening of the mounting plate Insert the power case into the flush ...

Страница 3: ... 6 N 230V AC L1 230V AC N DO1 DO2 DO3 DO4 Fan Low Fan Medium Fan High Valve H C 7 8 RT1 RT2 RTEXT OC RTEXT OC 1 0V AC 2 220V AC 3 Low 4 Med 5 High 6 Valve Attention Switching power is limited to 250VAC 300W 7 RT OC 8 RT OC 7 8 220V AC L 0V AC N 2 1 FAN 1 3 3 4 5 6 Valve RTEXT 7 8 43 1 7 88 3 5 21 0 8 30 1 2 30 1 2 88 3 5 Distance for mounting screws Horizontal and vertical 45 to 63mm 1 8 to 2 5 in...

Страница 4: ...FF based on weekdays and time may be programmed See chapter operation on how to program switch times A blinking clock indicates that the time needs to be set Time programs will not operate if the time is not defined See chapter operation advanced settings for instructions on how to set the time Occupation Sensor External Heat Cool change Auto change over Remotely control comfort and standby mode f...

Страница 5: ...ange Clock setup Time schedule The menu may be left by pressing the POWER button or by not pressing a button for more than 5 minutes Heat Cool Fan only change Pressing the OPTION button toggles Heating Cooling Fan only mode Access to Heat Cool change may be disabled with UP 03 Clock Setup and Time Schedule only available on Deluxe versions Clock Setup The current time is displayed in the small dig...

Страница 6: ...emperature loop may be changed Set point range is 15 to 30 C Changing of fan speeds Repeatedly pressing the fan speed button steps through low medium high and automatic fan speeds Automatic fan speed will not be activated in FAN ONLY mode Boost Pressing the boost button activates a 5 minute boost The output will be fully opened for the period of 5 minutes independent of demand This may be used to ...

Страница 7: ...may be modified now Use UP or DOWN buttons to adjust the value 8 After you are done press OPTION or POWER in order to return to the parameter selection level 9 Press the POWER button again so as to leave the menu The unit will return to normal operation if no button is pressed for more than 5 minutes User Parameters Parameter Description Setting Range Factory Setting UP 00 Enable change of operati...

Страница 8: ...lay OFF Prevents a too short running cycle for the heating or cooling stage by setting a minimum running time Delay OFF applies to all heating and cooling stages Delay ON Prevents a too short stopping cycle for heating or cooling stage by setting a minimum stopping time Delay ON applies to all heating and cooling stages Step by step switching In order to reduce the startup load of large fan motors...

Страница 9: ... and functionality of controller depend on its firmware revision It is therefore important to use a matching product version and parameter set The firmware version is shown on the large LCD digits when pressing UP and DOWN buttons for more than 3 seconds simultaneously Control Parameters Access Code 241 Warning Only experts should change these settings See user parameters for login procedure Param...

Отзывы: