Display: 

 

 

Display and change brightness, backlight, contrast, and colour settings 

 

 

 

Brightness   

Range: 0 ... 100%  

 

Default setting: 75% 

 

Backlight time 

Range: 10 ... 60 s      

 

Default setting: 30 s 

 

Contrast 

 

Range: 0 ... 100%  

 

Default setting: 50% 

 

Red 

 

Range: 0 ... 100%  

 

Default setting: 25% 

 

Green 

 

Range: 0 ... 100%  

 

Default setting: 55% 

 

Blue 

 

Range: 0 ... 100%  

 

Default setting: 40% 

 

 

Colour legend:  

 

(RGB colour = Red/green/blue)          Specified in percent 

 
 

 

 
 

 

 

 
 

Display-settings: 

 

 

Display or change automatic timing, daylight time, language, unit, floor temperature  

 

 

 

Automatic timing  

ON / OFF 

 

 

Default setting: ON 

 

 

 

OFF 

 Set date/time manually 

 

Daylight time  

OFF / ON 

 

 

Default setting: ON 

 

 

 

OFF 

 Set time manually  

 

Language 

 

German, English, and others 

 

 

 

 

 

 

Default setting: German 

 

Unit 

 

Celsius / Fahrenheit    

 

Default setting: Celsius 

 

Floor temperature 

OFF / ON 

 

 

 

 

 

ON 

 The floor temperature is displayed.  

 

 

 

(and, in addition, the floor temperature symbol) 

 

 

 

OFF 

 The room temperature is displayed. 

 

 

 

 

 

 

Default setting: OFF

 

SETUP: 

 

Display and change controller mode, sensor probe mode, offset settings, teach-in function, program,  

setback temperature 2, switching output, cooling controller, valve protection, switching cycle,  

supplementary heating, switching power 

 

 

 

Any  changes  in  the  SETUP  menu  can  lead  to  uncontrolled  functions  and  should  therefore 

 

only be performed by authorised electrical experts.

 

 

 

Controller mode  

Select 

 

 

 

Room temperature controller 

 

 

 

Floor temperature controller 

Default setting: Floor temperature  

 

 

 

 

 

 

controller 

 

 

 

Room temperature cont sensor 

 

 

 

Room temperature cont open window sensor (integrated shutdown; 

 

 

 

all the other controllers via external pluggable connector) 

 

 

After changing the controller mode, it is imperative for safety reasons to set it to "Frost protection" 

 

(check that the frost protection symbol is displayed); check the comfort and setback temperatures. 

 

 

Sensor type selection 

HRT sensor   

 

Default setting: Sensor 

 

 

 

10 k

Ω

 NTC, e.g. Busch-Jaeger 

 

 

 

12 k

Ω

 NTC, e.g. OJ 

 

 

 

15 k

Ω

 NTC, e.g. DEVI 

 

 

 

33 k

Ω

 NTC, e.g. Eberle 

 

 

 

  2 K

Ω

 PTC 

 

 

Room temperature offset  Measurement correction for the room temperature display 

 

 

 

Range: - 3.0 K ... 3.0 K    

Default setting: 0.00 °C 

 

 

Floor temperature offset  Measurement correction for the floor temperature display 

 

 

 

Range: - 3.0 K ... 3.0 K    

Default setting: 0.00 °C 

 

 

 

(floor and room temperature controllers with temperature monitoring only) 

 

 

Teach-in function 

Autonomous determination of the preheating time to be able to 

 

 

 

reach the selected comfort temperature 

 

 

 

OFF / ON 

 

 

Default setting: OFF 

 

 

Program 

 

Select block program or single day mode program 

 

 

 

 

 

 

Default setting: Block program 

 

 

Setback temperature 2 

Allows you to select a different setback temperature between the  

 

 

 

end of the comfort time 1 and the beginning of the comfort time 2 

 

 

 

OFF / ON 

 

 

Default setting: OFF 

 

 

Colour 

Red  Green  Blue    

Colour 

Red   Green  Blue 

Red 

100 

 

Orange  100 

65 

Green 

100 

 

Yellow 

100 

100 

Blue 

100   

Green 

50 

Fuchsia  100 

100   

Olive 

50 

50 

Purple 

100 

73 

100   

Maroon 

50 

White 

100 

100 

100    

Navy 

50 

Содержание ECOTIMER P

Страница 1: ...t with multi colour RGB LED backlit display Any colour can be selected in accordance with the customer s individual wishes The temperature controller is equipped with a current saving power supply unit which not only contributes to the saving of natural resources with 15 less energy consumption compared to conventional control units but thanks to lower energy consumption also helps to reduce your ...

Страница 2: ...red temperature Use the plus and minus keys to change the value use the back arrow to quit the menu If no inputs are made for 10s the display is reset to the default values To turn on the backlight press any key once Key lock Enable key lock Simultaneously press and hold down the keys 1 and 4 for 10s until the lock symbol is displayed Disable key lock Simultaneously press and hold down the keys 1 ...

Страница 3: ...setting Grouping New Group Add Group Comfort temperature times Programming of the comfort temperature times in block or single day mode Block mode Same time program for the workdays 1 to 5 1 Monday 2 Tuesday etc Weekend 6 Saturday 7 Sunday single day mode programming Daily changeable time program is selected in the SETUP menu Default settings Mon Fri Time 1 06 00 a m 09 00 a m Mon Fri Time 2 05 00...

Страница 4: ...re controller Default setting Floor temperature controller Room temperature controller sensor Room temperature controller open window sensor integrated shutdown all the other controllers via external pluggable connector After changing the controller mode it is imperative for safety reasons to set it to Frost protection check that the frost protection symbol is displayed check the comfort and setba...

Страница 5: ...ion MAC address number of total operating hours error messages factory default settings and the energy consumption Floor temperature display floor and room temperature controllers with temperature monitoring only Software version MAC address Operating hours Error messages Factory settings No Yes Default setting No Consumption Network Specify the network settings DHCP OFF ON Factory setting OFF IP ...

Страница 6: ...witch box It is connected as to be seen on the wiring diagram see illustration Make sure that the connection cables are straight their ends must be stripped by approx 5mm Installation height Approx 1 5m above the floor Attention Place the frame ring over the edges of the wallpaper Mount the controller on the mounting box by using thread forming tapping screws supplied with the box Then place the f...

Страница 7: ...ure controller Default sensor type HRT standard floor sensor Default room temperature offset 0 0 K Default floor temperature offset 0 0 K Teach in function Off Type of programming Block programming Comfort times Mon Fri 6 00 a m 9 00 a m 05 00 p m 10 00 p m Sat Son 6 00 a m 9 00 a m 05 00 p m 10 00 p m First setback temperature 3 C Second setback temperature Off Switching output inverted Off Cooli...

Страница 8: ...r than as intended are not covered by the liability for defects We do not assume liability arising from the consequences of improperly performed modifications or repair This also applies to the delivery of components and spare parts HRT does not assume liability for damage on the delivery item itself in particular not for indirect consequential damages or financial losses Disposal Disposal of elec...

Отзывы: