Universal controller HRT 6510-50

 

 

1. Description of function 

The HRT 6510 is a universal controller with integrated 

Powerline Module. 

To integrate it into your home network, use the 

existing

 

power line

. No WLAN connection is required. To connect the controller to your home network, use a powerline 

adapter. Range problems, losses in transmission, and environmental load arising from radio waves are thus a matter of the 
past. In addition to the conventional operation of the controller while at home, access to the temperature controller is also 

possible via a web-based user interface 

 at any time and from any location. 

The HRT 6510 is a universal temperature control unit with multi-colour RGB LED-backlit display. Any colour can be selected 
in accordance with the customer's individual wishes.

 

 

The temperature controller is equipped with a current-saving power supply unit which not only contributes to the saving of 
natural resources with 15% less energy consumption compared to conventional control units, but thanks to lower energy 

consumption also helps to reduce your energy costs. 

 

The device can be used as a  

 

Room temperature controller 

in the range between 5° and 30 °C, as a 

 

 

Floor temperature controller 

in the range between 10° and 40 °C, and as a

 

 

Room temperature controller with monitoring function: 

Room temperature: 5° ... 30 °C 
Floor temperature monitoring: 20° ... 40 °C 

 

Room temperature controller with window sensor:

 5 ... 30 °C 

 

Supplementary heating:

 Max. 120 min. in the range between 10 and 40 °C 

 

Cooling controller:

 5 ... 30 °C 

 

The configurations above can be made in the main menu under "Setup". By default, the control unit is configured as a floor 
temperature controller. 
 

 

Содержание ECOTIMER P

Страница 1: ...t with multi colour RGB LED backlit display Any colour can be selected in accordance with the customer s individual wishes The temperature controller is equipped with a current saving power supply unit which not only contributes to the saving of natural resources with 15 less energy consumption compared to conventional control units but thanks to lower energy consumption also helps to reduce your ...

Страница 2: ...red temperature Use the plus and minus keys to change the value use the back arrow to quit the menu If no inputs are made for 10s the display is reset to the default values To turn on the backlight press any key once Key lock Enable key lock Simultaneously press and hold down the keys 1 and 4 for 10s until the lock symbol is displayed Disable key lock Simultaneously press and hold down the keys 1 ...

Страница 3: ...setting Grouping New Group Add Group Comfort temperature times Programming of the comfort temperature times in block or single day mode Block mode Same time program for the workdays 1 to 5 1 Monday 2 Tuesday etc Weekend 6 Saturday 7 Sunday single day mode programming Daily changeable time program is selected in the SETUP menu Default settings Mon Fri Time 1 06 00 a m 09 00 a m Mon Fri Time 2 05 00...

Страница 4: ...re controller Default setting Floor temperature controller Room temperature controller sensor Room temperature controller open window sensor integrated shutdown all the other controllers via external pluggable connector After changing the controller mode it is imperative for safety reasons to set it to Frost protection check that the frost protection symbol is displayed check the comfort and setba...

Страница 5: ...ion MAC address number of total operating hours error messages factory default settings and the energy consumption Floor temperature display floor and room temperature controllers with temperature monitoring only Software version MAC address Operating hours Error messages Factory settings No Yes Default setting No Consumption Network Specify the network settings DHCP OFF ON Factory setting OFF IP ...

Страница 6: ...witch box It is connected as to be seen on the wiring diagram see illustration Make sure that the connection cables are straight their ends must be stripped by approx 5mm Installation height Approx 1 5m above the floor Attention Place the frame ring over the edges of the wallpaper Mount the controller on the mounting box by using thread forming tapping screws supplied with the box Then place the f...

Страница 7: ...ure controller Default sensor type HRT standard floor sensor Default room temperature offset 0 0 K Default floor temperature offset 0 0 K Teach in function Off Type of programming Block programming Comfort times Mon Fri 6 00 a m 9 00 a m 05 00 p m 10 00 p m Sat Son 6 00 a m 9 00 a m 05 00 p m 10 00 p m First setback temperature 3 C Second setback temperature Off Switching output inverted Off Cooli...

Страница 8: ...r than as intended are not covered by the liability for defects We do not assume liability arising from the consequences of improperly performed modifications or repair This also applies to the delivery of components and spare parts HRT does not assume liability for damage on the delivery item itself in particular not for indirect consequential damages or financial losses Disposal Disposal of elec...

Отзывы: