Fault
Fault reasons
Counter-measures
E0019 Motor overload
•
Improper setting of V/f curve
•
Mains supply voltage is too low
•
Normal motor runs for a long time
with heavy load at low speed
•
Motor locked-rotor or overload
•
Adjust V/f curve (F09.00 - F09.06)
•
Check the power input
•
Use special motor if the motor needs
to operate for a long time with heavy
load
•
Check the load and mechanical
transmission devices
E0021
Read / Write fault of
control board
EEPROM
•
Memory circuit fault of control board
EEPROM
•
Contact the supplier for repairing
E0022
Read / Write fault of
keypad EEPROM
•
Memory circuit fault of keypad
EEPROM
•
Replace the keypad
•
Contact the supplier for repairing
E0023
Faulty setting of
parameters
•
The power rating between motor and
inverter is too different
•
Improper setting of motor
parameters
•
Select an inverter with suitable power
rating
•
Set correct value of motor parameters
(F08.00 - F08.04)
E0024
Fault of external
equipment
•
Fault terminal of external equipment
operates
•
Check external equipment
E0028
SCI communication
timeout
•
Connection fault of Communication
cable
•
Disconnected or not well connected
•
Check the connection
E0029
SCI communication
error
•
Connection fault of communication
cable
•
Disconnected or not well connected
•
Communication setting error
•
Communication data error
•
Check the connection
•
Check the connection
•
Correctly set the communication
format (F17.00) and the baud rate
(F17.01)
•
Send the data according to MODBUS
protocol
E0030 Brake fault
•
Brake contactor does not act
•
Brake contactor is damaged
•
Brake contactor is nornally run, but
there is no feedback signal
•
Check wiring of brake
•
Replace brake contactor
•
Check feedback wiring
E0032
Brake releasing is
abnormal
•
Detection time for brake releasing
abnormal is too short
•
Brake releasing current/torque is too
high
•
Properly set detection time for brake
releasing
•
Adjust brake releasing current/torque
Note:
E0022 does not affect the normal use of inverter.