Chapter 5 Technical Data
Shenzhen Hpmont Technology Co., Ltd.
-
16
-
HD09 Series User Manual V1.1
5.1.2
Power Terminal Lug
The wiring lugs of the power terminals (round bare terminals) can be selected according to the
terminal wiring specifications, screw size, and the maximum outside diameter of the wiring lugs.
Size
Size A
Size B
Screw size
M3 M3.5
Tightening torque (N. M)
0.6 - 0.8
0.8 - 1.2
Max. outer diameter of lug
d (mm)
6.1 7
5.2
Braking Resistor
Model
Resistance Value (Ω)
Resistance Power (W)
HD09-4T0P4G
300 - 400
80
HD09-4T0P7G
250 - 350
100
HD09-4T1P5G
200 - 300
200
HD09-4T2P2G
150 - 250
250
HD09-4T4P0G
100 - 150
300
HD09-4T5P5G 80
-
100
500
Note:
Braking unit is built in three-phase model type exclusively.
d