Walk Test
Turn the wall switch on. The light/s should turn on
immediately and will remain on while the detection unit
warms up, for approximately 40 seconds. It will then
turn off. Do a walk test and the light should turn on.
This confirms that the wiring is correct and that the
light is operational. Walk through the coverage area and
adjust the Light Patrol according to your needs. Wait for
about 5 seconds between each walk test. You may need to
insert plastic blinkers (see page 2).
Time adjustment
The time adjustment controls how long the light/s will
stay on after movement is detected. This time varies
between approximately 7 minutes (extreme clockwise) to
approximately 8 seconds (extreme anti-clockwise).
Light adjustment
The light or lux adjustment controls the light level at which
the Light Patrol will switch on when in Auto Mode. At the
fully clockwise position the unit will operate and sense
movement 24 hours a day. At the fully anti-clockwise setting
the unit will operate only at night. To obtain the correct
setting turn knob clockwise until the light comes on at the
desired lux level.
Manual override (Cat 630/3 only)
There will be times when you wish the light to stay on
regardless of motion. This may easily be achieved by
turning the light off and on again within 1 -2 seconds. The
light/s will now remain on until manually switched off.
To return the Light Patrol to the Auto Mode turn the
power
‘off’
for longer than 10 seconds and then switch
back on. Cat 630/3A and 630/3ABL requires special wiring
for manual override (see figure 5).
Cat 630/3A and 630/3ABL.
Wiring to terminal block.
Cat 630/3A and 630/3ABL with
by-pass switch. Protected position.
Under eave if possible.
Turn the time control ( ) anti-clockwise and the light
control ( ) clockwise to the test position (see figure 4.)
8
Test mode
Figure 4.
TESTposition
Figure 5.
Terminal Block
BaseCover
Your Lamp
NEUTRAL(N)
ACTIVE(L)
BOTTOM
Switch
RED
GASKET
WIRING DIAGRAM
BROWN
BLUE
L
N
L
Wiring to terminal block. Cat 630/3 only.
Protected position. Under eave if possible.
Figure 3.
•
Route cable from the light/s and cable from the
power source to the terminal block.
•
Strip approximately 6 -8mm insulation from the
cables for insertion into the terminal block.
•
Run the power and light wires through the gasket
hole and connect to the terminal block (see
figure 3.)
•
Connect the neutral from power source to N.
Connect the active from the power source to L.
(Refer to terminal block for positioning on base
cover).
•
Connect neutral from light/s to N. Connect active
from the light/s to L. (see figure 3.)
•
Position terminal block and screw main unit of
Light Patrol to the base cover.
•
A terminal is provided for terminating an earthing
conductor. However, it is not compulsory to do this.
7
Wiring instructions