Walk Test

Turn the wall switch on. The light/s should turn on  
immediately and will remain on while the detection unit  
warms up, for approximately 40 seconds. It will then  
turn off. Do a walk test and the light should turn on.
This confirms that the wiring is correct and that the  
light is operational. Walk through the coverage area and  
adjust the Light Patrol according to your needs. Wait for  
about 5 seconds between each walk test. You may need  to 
insert plastic blinkers (see page 2).

Time adjustment

The time adjustment controls how long the light/s will  
stay on after movement is detected. This time varies  
between approximately 7 minutes (extreme clockwise) to  
approximately 8 seconds (extreme anti-clockwise).

Light adjustment

The light or lux adjustment controls the light level at which  
the Light Patrol will switch on when in Auto Mode. At the
fully clockwise position the unit will operate and sense
movement  24 hours a day. At the fully anti-clockwise setting
the unit will operate only at night. To obtain the correct 
setting turn knob clockwise until the light comes on at the
desired lux level.

Manual override (Cat 630/3 only)

There will be times when you wish the light to stay on  
regardless of motion. This may easily be achieved by  
turning the light off and on again within 1 -2 seconds.  The 
light/s will now remain on until manually switched off.
To return the Light Patrol to the Auto Mode turn the 
power 

‘off’ 

for longer than 10 seconds and then switch 

back on. Cat 630/3A and 630/3ABL requires special wiring 
for manual override (see figure 5).

Cat 630/3A and 630/3ABL.  
Wiring to terminal block.

Cat 630/3A and 630/3ABL with
by-pass switch. Protected position.  

Under eave if possible.

Turn the time control ( ) anti-clockwise and the light  
control ( )  clockwise to the test position (see figure 4.)

8

Test mode

Figure 4.

TESTposition

Figure 5.

Terminal Block

BaseCover

Your Lamp

NEUTRAL(N) 

ACTIVE(L)

BOTTOM

Switch

RED

GASKET

WIRING DIAGRAM

BROWN

BLUE

L  

N  

L

Wiring to terminal block. Cat 630/3 only.

Protected position. Under eave if possible.

Figure 3.

Route cable from the light/s and cable from the  
power source to the terminal block.

Strip approximately 6 -8mm insulation from the  
cables for insertion into the terminal block.

Run the power and light wires through the gasket  
hole and connect to the terminal block (see  
figure 3.)

Connect the neutral from power source to N.  
Connect the active from the power source to L.  
(Refer to terminal block for positioning on base  
cover).

Connect neutral from light/s to N. Connect active  
from the light/s to L. (see figure 3.)

Position terminal block and screw main unit of  
Light Patrol to the base cover.

A terminal is provided for terminating an earthing  
conductor. However, it is not compulsory to do this.

7

Wiring instructions

Содержание 630/3

Страница 1: ...efore installing 3 Make sure the power wiring comes from a circuit protected by a suitable fuse or circuit breaker 4 For outdoor installation a location under eaves is preferable 5 This unit must be installed by a licensed electrician according to local codes and regulations 3 Features 4 Wheninstallingthesecuritysensorpay specialattentiontothesepoints Directed at swimming pools and ponds The movem...

Страница 2: ... shared depending on the problem that you are attempting to overcome see figure 1 2 Before installation make sure that the power is off on that particular circuit Remove the fuse or turn off the circuit breaker at the switchboard 3 Choose a mounting position approximately 2 metres above the area that you wish to monitor The unit may be mounted to a height of 4 metres 4 Remove the base cover and sc...

Страница 3: ... within 1 2 seconds The light s will now remain on until manually switched off To return the Light Patrol to the Auto Mode turn the power off for longer than 10 seconds and then switch back on Cat 630 3A and 630 3ABL requires special wiring for manual override see figure 5 Cat 630 3A and 630 3ABL Wiring to terminal block Cat 630 3A and 630 3ABL with by pass switch Protected position Under eave if ...

Страница 4: ... 1 Power not available Check connections switches and fuse 2 Faulty globe Replace globe 3 Incorrect wiring Recheck all wiring 4 Controls incorrectly set Change detection angle Change light adjustment 5 Sensor positioned in wrong direction Change position and direction of sensor Light switches on for no apparent reason 1 Air conditioner heater vents in proximity of sensor Reposition and redirect se...

Отзывы: