Figure 11: Configure library, basic control path failover configuration disabled
In
Figure 12: Configure library, basic control path failover configuration available
configuration requirements for enabling basic control path failover have been met and the library has
made the option for
Enable Library Control Path Failover
selectable as well as providing a selection for
the “Alternate Drive for Library Control Path.”
Figure 12: Configure library, basic control path failover configuration available
The “Enable Library Control Path Failover” setting is not selectable
Symptom
In the RMI
Configuration > System
screen, the setting
Enable Library Control Path Failover
cannot
be selected.
Cause
The prerequisites for control path failover have not been met.
The “Enable Library Control Path Failover” setting is not selectable
41