HPE 800W Flex Slot Titanium Hot-plug Low Halogen Power Supply
on page 120
•
HPE 800W Flex Slot Universal Hot-plug Low Halogen Power Supply
on page 121
For detailed power supply specifications, see the QuickSpecs on the
.
HPE 500W Low Halogen Non-hot-plug Power Supply
Specification
Value
Input requirements
—
Rated input voltage
100 VAC to 240 VAC
240 VDC for China only
Rated input frequency
50 Hz to 60 Hz
Rated input current
5.8 A at 100 VAC
2.3 A at 240 VAC
2.7 A at 240 VDC for China only
Maximum rated input power
578 W at 100 VAC
557 W at 240 VAC
BTUs per hour
1953 at 100 VAC
1882 at 240 VAC
Power supply output
—
Rated steady-state power
500 W at 100 VAC to 240 VAC input
500 W at 240 VDC input for China only
Maximum peak power
500 W at 100 VAC to 240 VAC input
500 W at 240 VDC input for China only
HPE 500W Flex Slot Platinum Hot-plug Low Halogen Power Supply
Specification
Value
Input requirements
—
Rated input voltage
100 VAC to 240 VAC
240 VDC for China only
Rated input frequency
50 Hz to 60 Hz
Not applicable to 240 VDC
Table Continued
118
Specifications
Содержание ProLiant DL160 Gen10
Страница 14: ...14 Customer self repair ...
Страница 15: ...Customer self repair 15 ...
Страница 16: ...16 Customer self repair ...
Страница 17: ...Customer self repair 17 ...
Страница 43: ...b Remove the rail from the server 9 Remove the non hot plug power supply Removal and replacement procedures 43 ...
Страница 107: ...Front I O and thermal ambient sensor cabling USB 3 0 cabling Cabling 107 ...
Страница 113: ...Slot 2 Slot 3 Cabling 113 ...
Страница 116: ...Chassis Intrusion Detection switch cabling NOTE Cabling is the same for both LFF and SFF configurations 116 Cabling ...