Specifications
Environmental specifications
Specification
Value
—
Operating
10°C to 35°C (50°F to 95°F)
Nonoperating
-30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)
—
Operating
8% to 90%
28°C (82.4°F), maximum wet bulb temperature
Nonoperating
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1000 ft) to 3050 m
(10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The
upper limit and rate of change might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
• 5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of
1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m
(10,000 ft).
• 40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F
per every 410 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft).
The approved hardware configurations for this system are listed on the
.
Mechanical specifications
Specification
Value
Height
4.29 cm (1.69 in)
Depth
61.50 cm (24.21 in)
Width
43.46 cm (17.11 in)
Weight (approximate range)
10.00 kg to 16.00 kg (22.03 lb to 35.27 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HPE 500W Low Halogen Non-hot-plug Power Supply
on page 118
•
HPE 500W Flex Slot Platinum Hot-plug Low Halogen Power Supply
on page 118
•
HPE 800W Flex Slot Platinum Hot-plug Low Halogen Power Supply
on page 119
Specifications
117
Содержание ProLiant DL160 Gen10
Страница 14: ...14 Customer self repair ...
Страница 15: ...Customer self repair 15 ...
Страница 16: ...16 Customer self repair ...
Страница 17: ...Customer self repair 17 ...
Страница 43: ...b Remove the rail from the server 9 Remove the non hot plug power supply Removal and replacement procedures 43 ...
Страница 107: ...Front I O and thermal ambient sensor cabling USB 3 0 cabling Cabling 107 ...
Страница 113: ...Slot 2 Slot 3 Cabling 113 ...
Страница 116: ...Chassis Intrusion Detection switch cabling NOTE Cabling is the same for both LFF and SFF configurations 116 Cabling ...