Installing the HPE Smart Storage Battery
WARNING:
The server blade may contain internal replaceable battery cells or battery packs. A risk
of fire, burns, or explosions exists if the battery pack is not properly handled. To reduce the risk of
personal injury:
• Do not attempt to recharge the battery outside of the installed application.
• Do not expose the battery to temperatures higher than 60°C (140°F).
• Do not disassemble, crush, puncture, short external contacts, or dispose of the battery in fire or
water.
• Replace only with the Hewlett Packard Enterprise spare battery designated for this product.
Dispose of used batteries according to the manufacturer's instructions and local disposal
requirements.
• For battery holders (for example, coin cells), observe the correct polarity when changing the
battery/cell. A danger of explosion exists if the battery is installed incorrectly.
System ROM and firmware messages may display "energy pack" in place of "Smart Storage Battery."
Energy pack refers to both HPE Smart Storage Batteries and HPE Smart Storage Hybrid Capacitors.
Procedure
1.
on page 21.
2.
on page 22.
3.
Place the server blade on a flat, level work surface.
4.
on page 22.
5.
If installed, remove the direct connect SATA cable (
Remove the direct connect SATA cable
on
page 31).
6.
If installed, remove the internal USB drive.
To locate the internal USB connector, see
on page 13.
7.
Remove the right DIMM baffle (
on page 23).
8.
Install the HPE Smart Storage Battery on the right DIMM baffle.
Hardware options installation
51