156
receives a portal packet within a detection timeout (
timeout
timeout
) and the portal packet is valid,
the device considers the portal authentication server to be reachable. Otherwise, the device
considers the portal authentication server to be unreachable.
Portal packets include user login packets, user logout packets, and heartbeat packets. Heartbeat
packets are periodically sent by a server. By detecting heartbeat packets, the device can detect the
server's actual status more quickly than by detecting other portal packets.
The portal authentication server detection feature takes effect only when the device has a
portal-enabled interface.
Only the IMC portal authentication server supports sending heartbeat packets. To test server
reachability by detecting heartbeat packets, you must enable the server heartbeat feature on the
IMC portal authentication server.
The detection timeout (
timeout
timeout
) configured on the device must be greater than the server
heartbeat interval configured on the portal authentication server.
You can configure the device to take one or more of the following actions when the server
reachability status changes:
•
Sending a log message, which contains the name, the current state, and the original state of the
portal authentication server.
•
Enabling portal fail-permit. When the portal authentication server is unreachable, the portal
fail-permit feature on an interface allows users on the interface to have network access. When
the server recovers, it resumes portal authentication on the interface. For more information, see
"
Configuring the portal fail-permit feature
To configure portal authentication server detection:
Step Command
Remarks
1.
Enter system view.
system-view
N/A-
2.
Enter portal
authentication server
view.
portal server
server-name
N/A
3.
Configure portal
authentication server
detection.
server-detect
[
timeout
timeout
]
log
By default, portal authentication
server detection is disabled.
This feature takes effect
regardless of whether portal
authentication is enabled on an
interface or not.
Configuring portal Web server detection
A portal authentication process cannot complete if the communication between the access device
and the portal Web server is broken. To address this problem, you can enable portal Web server
detection on the access device.
With the portal Web server detection feature, the access device simulates a Web access process to
initiate a TCP connection to the portal Web server. If the TCP connection can be established
successfully, the access device considers the detection successful, and the portal Web server is
reachable. Otherwise, it considers the detection to have failed. Portal authentication status on
interfaces of the access device does not affect the portal Web server detection feature.
The portal Web server detection feature takes effect only when a URL is specified for the portal Web
server and the device has a portal-enabled interface.
You can configure the following detection parameters:
•