background image

19 

VDP resource-wait-delay 
exponent  

Calculated value 
(seconds) 

Result value (seconds) 

23 83.88608 

84 

24 167.77216 

168 

25 335.54432 

336 

26 671.08864 

672 

27 1342.17728 

1343 

28 2684.35456 

2685 

29 5368.70912 

5369 

30 10737.41824 

10738 

31 21474.83648 

21475 

 

Examples 

# Configure the VDP resource-wait-delay exponent on Ten-GigabitEthernet 1/0/1 as 

23

<Sysname> system-view 

[Sysname] interface ten-gigabitethernet 1/0/1 

[Sysname-Ten-GigabitEthernet1/0/1] evb vdp timer resource-wait-delay exponent 23 

# Configure the VDP resource-wait-delay exponent on Bridge-Aggregation 1 as 

23

<Sysname> system-view 

[Sysname] interface bridge-aggregation 1 

[Sysname-Bridge-Aggregation1] evb vdp timer resource-wait-delay exponent 23 

evb vsi 

Use 

evb vsi

 to create a VSI interface or VSI aggregate interface. 

Use 

undo evb vsi

 to remove a VSI interface or VSI aggregate interface. 

Syntax 

evb vsi

 

vsi-local-id

 { 

association

 | 

pre-association

 } 

undo evb vsi

 

vsi-local-id 

Default 

No VSI interface or VSI aggregate interface exists on an S-channel. 

Views 

S-channel interface view, S-channel aggregate interface view 

Predefined user roles 

network-admin 

Parameters 

vsi-local-id

: Specifies a VSI local ID in the range of 0 to 1023. 

association

: Specifies the association property. On a VSI interface with the association property, all 

filters immediately take effect. 

pre-association

: Specifies the pre-association property. On a VSI interface with the pre-association 

property, VLAN filters take effect, but <VLAN, MAC> filters are not effective.  

Содержание 5900 series

Страница 1: ...HPE 5920 5900 Switch Series EVB Command Reference Part number 5998 6626s Software version Release 2422P01 Document version 6W101 20171030 ...

Страница 2: ...Software Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under vendor s standard commercial license Links to third party websites take you outside the Hewlett Packard Enterprise website Hewlett Packard Enterprise has no control over and is not responsible for information outside the Hewlett Packard Enterprise website Acknowledgments Intel ...

Страница 3: ...relay 14 evb s channel 15 evb vdp timer keepalive exponent 16 evb vdp timer resource wait delay exponent 18 evb vsi 19 evb vsi active 20 evb vsi filter 21 interface 23 reset counters interface 24 shutdown 25 Document conventions and icons 26 Conventions 26 Network topology icons 27 Support and other resources 28 Accessing Hewlett Packard Enterprise Support 28 Accessing updates 28 Websites 29 Custo...

Страница 4: ...ser roles network admin Parameters bandwidth value Specifies the expected bandwidth in the range of 1 to 400000000 kbps Examples Set the expected bandwidth of S Channel 1 0 1 10 to 2000000 kbps Sysname system view Sysname interface s channel 1 0 1 10 Sysname S Channel1 0 1 10 bandwidth 2000000 Set the expected bandwidth of S Channel 1 0 1 10 1 to 2000000 kbps Sysname system view Sysname interface ...

Страница 5: ...0 default Restore the default settings for S Channel 1 0 1 10 1 Sysname system view Sysname interface s channel 1 0 1 10 1 Sysname S Channel1 0 1 10 1 default description Use description to configure a description for an interface Use undo description to restore the default Syntax description text undo description Default The default description for an interface is interface name Interface The fol...

Страница 6: ...Aggregation to lab Sysname system view Sysname interface schannel aggregation 1 10 1 Sysname Schannel Aggregation1 10 1 description VSI Aggregation to lab display evb cdcp Use display evb cdcp to display CDCP negotiation information Syntax display evb cdcp interface interface type interface number Views Any view Predefined user roles network admin network operator Parameters interface interface ty...

Страница 7: ... tlv Use display evb evb tlv to display S channel EVB TLV negotiation information Syntax display evb evb tlv interface interface type interface number interface number channel id Views Any view Predefined user roles network admin network operator Parameters interface Specifies an interface If you do not specify an interface the command displays EVB TLV negotiation information for all interfaces wi...

Страница 8: ...upported Remote RR request status Not requested Remote RR status Unknown Max ECP retry time Local 3 Remote NA Operative 3 ULPPDU retransmission exponent Local 16 Remote NA Operative 16 Resource wait delay exponent Local 20 Remote NA Operative 20 Reinit keep alive exponent Local 25 Remote NA Operative 25 Table 2 Command output Field Description EVB mode EVB mode bridge EVB bridge station EVB statio...

Страница 9: ...Local negotiation value Remote negotiation value Operative value NA means no value is set on the remote EVB station display evb s channel Use display evb s channel to display S channel information Syntax display evb s channel interface interface type interface number Views Any view Predefined user roles network admin network operator Parameters interface interface type interface number Specifies a...

Страница 10: ... summary Default manager ID 192 168 1 1 Port number 80 Interface S Channel number VSI number XGE1 0 1 2 2 Table 4 Command output Field Description Default manager ID Address or name of the default VSI manager Port number Port number of the default VSI manager Interface Name of the interface with EVB enabled S channel number Number of S channels VSI number Number of VSI interfaces display evb vsi U...

Страница 11: ...channel interface or S channel aggregate interface The interface number channel id vsi local id argument specifies a VSI interface or VSI aggregate interface Examples Display brief VSI interface information for Ten GigabitEthernet 1 0 1 Sysname display evb vsi interface ten gigabitethernet 1 0 1 Status A Association P Pre association VSI VTID Type Instance Status interface version ID SCH1 0 1 100 ...

Страница 12: ... destination MAC for the traffic and the VLAN to which the traffic belongs In the format GroupID VLAN ID meaning the VLAN to which the traffic belongs and the group to which the VLAN belongs In the format GroupID MAC address VLAN ID meaning the destination MAC for the traffic the VLAN to which the traffic belongs and the group to which the VLAN belongs display interface Use display interface to di...

Страница 13: ...eyword the command displays information about all interfaces If you specify the s channel keyword but do not specify an S channel interface or VSI interface the command displays information about all created S channel interfaces and VSI interfaces Examples Display detailed information about S Channel 1 0 1 10 Sysname display interface s channel 1 0 1 10 S Channel1 0 1 10 Current state UP IP Packet...

Страница 14: ...SCH1 0 1 11 1 DOWN Not connected Table 6 Command output Field Description Current state Interface status Administratively DOWN The interface is administratively down DOWN The interface is administratively up but physically down UP The interface is both administratively and physically up Hardware Address Hardware address of the interface Description Description information for the interface Bandwid...

Страница 15: ...commands reset counters interface evb default manager Use evb default manager to specify the default VSI manager Use undo evb default manager to restore the default Syntax evb default manager ip ip address ipv6 ipv6 address name name port port number local server undo evb default manager Default The default VSI manager is not specified Views System view Predefined user roles network admin Paramete...

Страница 16: ...VB on an interface Do not enable EVB on a member port of an aggregation group or add a member port with EVB enabled into an aggregation group Otherwise an error message appears Restore all default settings for an interface before enabling EVB on the interface A default S channel is created on an interface after EVB is enabled on the interface with both SCID and SVID as 1 After an S channel is crea...

Страница 17: ...annel with the RR mode disabled do not disable its MAC address learning function Otherwise the EVB bridge might fail to forward traffic from VMs on the EVB station After you disable the MAC address learning function for an S channel packets with an unknown source MAC address are discarded Examples Disable the MAC address learning function on S Channel 1 0 1 10 Sysname system view Sysname interface...

Страница 18: ...ually enable or disable the RR mode for an S channel Examples Enable the RR mode on S Channel 1 0 1 10 Sysname system view Sysname interface s channel 1 0 1 10 Sysname S Channel1 0 1 10 evb reflective relay Enable the RR mode on Schannel Aggregation 1 10 Sysname system view Sysname interface schannel aggregation 1 10 Sysname Schannel Aggregation1 10 evb reflective relay evb s channel Use evb s cha...

Страница 19: ...nel aggregate interface A manually created S channel interface or S channel aggregate interface operates in access mode and an S channel interface or S channel aggregate interface that is automatically created through CDCP operates in trunk mode Create an S channel on an interface with EVB enabled Otherwise an error message appears When you manually create an S channel do not use the SCID or SVID ...

Страница 20: ...e VDP keepalive time These two variables use the larger values proposed by the station and bridge through EVB TLV The network environment and configurations on the EVB bridge and station determine whether to use the defaults or the actual proposed values for the following ECP values ECP maximum retransmission time ECP retransmission exponent Table 7 Values for VDP keepalive time VDP keepalive expo...

Страница 21: ...estore the default Syntax evb vdp timer resource wait delay exponent value undo evb vdp timer resource wait delay exponent Default The VDP resource wait delay exponent is 20 Views Layer 2 Ethernet interface view Layer 2 aggregate interface view Predefined user roles network admin Parameters value Specifies a VDP resource wait delay exponent in the range of 15 to 31 Usage guidelines The value for V...

Страница 22: ...regation1 evb vdp timer resource wait delay exponent 23 evb vsi Use evb vsi to create a VSI interface or VSI aggregate interface Use undo evb vsi to remove a VSI interface or VSI aggregate interface Syntax evb vsi vsi local id association pre association undo evb vsi vsi local id Default No VSI interface or VSI aggregate interface exists on an S channel Views S channel interface view S channel agg...

Страница 23: ...e pre association to association for a VSI interface the EVB bridge sets the VM s MAC address After creating a VSI interface or VSI aggregate interface you can enter VSI interface view or VSI aggregate interface view by executing the interface command Examples Create a VSI interface on S Channel 1 0 1 10 with VSI local ID 1 and the association property Sysname system view Sysname interface s chann...

Страница 24: ...Related commands evb vsi filter evb vsi filter Use evb vsi filter to configure a VSI filter Use undo evb vsi filter to remove a VSI filter Syntax evb vsi filter group group id vlan vlan id mac mac address undo evb vsi filter group group id vlan vlan id mac mac address Default No VSI filter exists Views VSI interface view VSI aggregate interface view Predefined user roles network admin Parameters g...

Страница 25: ...hese guidelines Before you configure a VSI filter on a VSI aggregate interface make sure the S channel aggregate interface to which the VSI aggregate interface belongs operates in trunk mode Otherwise the VSI filter configuration fails After you configure a VSI filter on a VSI aggregate interface an S channel aggregate interface automatically permits the VLAN that is configured in the VSI filter f...

Страница 26: ...es the ID of the S channel interface number channel id vsi local id Specifies a VSI interface or VSI aggregate interface by its ID The interface number argument specifies the interface where the S channel resides The channel id argument specifies the ID of the S channel The vsi local id argument specifies the local ID of the VSI Examples Enter the view of S channel interface S Channel 1 0 1 10 Sys...

Страница 27: ...of the S channel The vsi local id argument specifies the local ID of the VSI Usage guidelines Follow these guidelines when you clear statistics for an S channel interface an S channel aggregate interface a VSI interface or a VSI aggregate interface To collect traffic statistics for an S channel interface S channel aggregate interface VSI interface or a VSI aggregate interface in a certain period u...

Страница 28: ...own Default An S channel interface S channel aggregate interface VSI interface or a VSI aggregate interface is up Views S channel interface view S channel aggregate interface view Predefined user roles network admin Examples Shut down S Channel 1 0 1 10 Sysname system view Sysname interface s channel 1 0 1 10 Sysname S Channel1 0 1 10 shutdown Shut down Schannel Aggregation 1 10 Sysname system vie...

Страница 29: ...st one x y Asterisk marked square brackets enclose optional syntax choices separated by vertical bars from which you select one choice multiple choices or none 1 n The argument or keyword and argument combination before the ampersand sign can be entered 1 to n times A line that starts with a pound sign is comments GUI conventions Convention Description Boldface Window names button names field name...

Страница 30: ... Represents an access controller a unified wired WLAN module or the access controller engine on a unified wired WLAN switch Represents an access point Represents a wireless terminator unit Represents a wireless terminator Represents a mesh access point Represents omnidirectional signals Represents directional signals Represents a security product such as a firewall UTM multiservice security gatewa...

Страница 31: ...s provide a mechanism for accessing software updates through the product interface Review your product documentation to identify the recommended software update method To download product updates go to either of the following Hewlett Packard Enterprise Support Center Get connected with updates page www hpe com support e updates Software Depot website www hpe com support softwaredepot To view and u...

Страница 32: ...r self repair CSR programs allow you to repair your product If a CSR part needs to be replaced it will be shipped directly to you so that you can install it at your convenience Some parts do not qualify for CSR Your Hewlett Packard Enterprise authorized service provider will determine whether a repair can be accomplished by CSR For more information about CSR contact your local service provider or ...

Страница 33: ...umber edition and publication date located on the front cover of the document For online help content include the product name product version help edition and publication date located on the legal notices page ...

Страница 34: ... evb vsi 7 display interface 9 Documentation feedback 29 E evb default manager 12 evb enable 13 evb mac learning forbidden 14 evb reflective relay 14 evb s channel 15 evb vdp timer keepalive exponent 16 evb vdp timer resource wait delay exponent 18 evb vsi 19 evb vsi active 20 evb vsi filter 21 I interface 23 R Remote support 29 reset counters interface 24 S shutdown 25 W Websites 29 ...

Отзывы: