technical reference guide
3–23
System Configuration
baseboard management controller (BMC)
This section explains the BMC command-line interface. Topics include:
■
Using the BMC command line interface (CLI), page 3-23
■
BMC commands, page 3-24
using the BMC command line interface (CLI)
To log in to the BMC command line interface, use a serial connection and terminal emulation
software:
1. With the workstation turned off, connect a null-modem cable to
Serial Port 1
on the rear
panel of the workstation (see page 17), and to your remote device.
2. Configure the terminal emulation software with these settings:
❏
Baud rate: 9600
❏
Bits: 8
❏
Parity: None
❏
Stop Bits: 1 (one)
❏
Flow Control: XON/XOFF
NOTE:
The default terminal emulation type is VT100+. Terminal emulation for the BMC cannot
be changed. The default baud rate is 9600. This setting can be changed using the EFI
baud
command.
3. Using the terminal emulation, connect to the workstation with a
direct connection
.
4. To access the BMC command line interface, press
Esc (
For example, on a U.S. QWERTY keyboard, press
Esc
, then press
Shift
and
9
at the same
time.
5. If prompted, enter the user or admin password at the login prompt:
login>
If no password is defined, you are not prompted for one.
NOTE:
If AC power is connected to the system, this command activates the BMC command line
interface even if the workstation power is off.
6. The BMC prompt displays. If you entered the admin password, you have full access. If you
entered the user password, you have restricted access.
Admin Session Initiated
cli>
or
User Session Initiated
cli>