technical reference guide
D–7
Event, Error and Warning Messages
IPMI Origins
For example:
Data2 Data3
80
03
ipmi req from the CLI thd for CHASSIS_CONTROL_POWER_DOWN (“p 0”)
81
03
ipmi req from the CLI thd for CHASSIS_CONTROL_POWER_UP (“p 1”)
80
01
ipmi req from via BT for CHASSIS_CONTROL_POWER_DOWN
83
03
ipmi/RS req from the CLI thd for CHASSIS_CONTROL_HARD_RESET
00
FA
CHASSIS_CONTROL_POWER_DOWN req from the ACPI sensor (S5)
00
D9
CHASSIS_CONTROL_POWER_DOWN req from CPU0 temp sensor
01
0E
CHASSIS_CONTROL_POWER_UP req from WakeOnLan sensor
Number
Source
0x01 BT
0x03 CLI
0x07 IPMB
0x08
I2C1
0x09 I2C2
0x0F KCS0
0x10 KCS1
0x11 KCS2
0x1F
System power thread
(Used by Power Restore Policy)