2–26
technical reference guide
Installing or Replacing Parts and Accessories
airflow guide
The airflow guide on your system ensures that the proper volume of air for cooling the voltage
regulator modules (VRMs), processor, and processor power module flows over these
components.
You may need to replace the airflow guide if it becomes damaged to the point that airflow across
the processor is restricted. You may need to remove the airflow guide to gain access to
components under it.
removing the airflow guide
1. Turn off the system and
disconnect all power
.
2. Disconnect all cables, and remove the system covers.
3. Raise the hard drive cage and remove the AGP retainer arm.
4. Lift the airflow guide out of the system chassis.
Airflow Guide
replacing the airflow guide
1. Insert the airflow guide so the CPU assembly fits into the opening in the guide.
2. Lower the hard drive cage, making sure it lowers fully and fits firmly against the airflow
guide and replace the AGP retainer arm.
3. Replace the system covers and reconnect all cables.