Fault notification and recovery
Fault notification and recovery features combine innovative hardware and software technology to
prevent the loss of critical data and minimize unplanned downtime.
If the workstation is connected to a network that is managed by HP CMS, the workstation sends a fault
notice to the network management application. With HP CMS, you can also remotely schedule
diagnostics to run on managed PCs and create a summary report of failed tests.
Drive Protection System
The Drive Protection System (DPS) is a diagnostic tool built into hard disk drives and is installed in select
HP workstations. The DPS helps diagnose problems that might result in unwarranted hard disk drive
replacement.
When HP workstations are built, each installed hard disk drive is tested using the DPS, and a permanent
record of key information is written onto each drive. Every time the DPS is run, test results are written
to the hard disk drive. The service provider can use this information to help diagnose conditions that
required you to run the DPS software.
ECC fault prediction
When the workstation encounters an excessive number of error checking and correcting (ECC) memory
errors, it displays a local alert message. This message contains information about the errant DIMM,
enabling you to take action before you experience noncorrectable memory errors. ECC DIMMs are
standard on this workstation.
Thermal sensors
Several thermal sensors in the HP Workstation regulate workstation fans to maintain an acceptable,
efficient chassis temperature.
60
Chapter 4 System management
ENWW
Содержание Workstation Z600
Страница 1: ...HP 600 Workstation Maintenance and Service Guide ...
Страница 4: ...iv About this guide ENWW ...