Installing the SFF flash adapter option
CAUTION:
To prevent improper cooling and thermal damage, do not operate the compute module or the enclosure
unless all drive and device bays are populated with either a component or a blank.
Prequisites
The SFF flash adapter option is supported when any of the following components are installed:
• HPE Dynamic Smart Array B140i Controller
• HPE Smart Array P240nr Controller
• HPE H240nr Host Bus Adapter
• HPE Smart Array P542D Controller (with HPE Synergy 480 Gen9 compute module backplane installed)
To install the component:
Procedure
1.
Remove the drive blank.
2.
Install the uFF drives in the SFF flash adapter.
3.
Install the SFF flash adapter by pushing firmly near the left-side adapter ejection handle until the latching
spring engages in the drive bay.
Installing the controller option
For more information about supported options, see the product QuickSpecs on the
.
CAUTION:
Hewlett Packard Enterprise recommends performing a complete backup of all compute module data
before performing a controller or adapter installation or removal.
28
Installing the SFF flash adapter option
Содержание Synergy 480 Gen9