SCSI-2 Drive Command Set
Write Buffer Command (3BH)
Chapter 2
2-100
Buffer Offset
Indicates at what address the data is written, offset
from the beginning of the buffer. Must be set to 0 when
using Download Microcode ID.
Parameter List
Length
Indicates the number of data bytes to be written in the
buffer.
Buffer RAM
Indicates the data buffer space used for transfer to and
from the optical disk.
Download
Microcode
Indicates the code the drive uses to operate.
Serial Number and
Manufacturing
Date Cod
e
Indicates the drive’s serial number and date code, which
indicates the week of manufacturing.
Customer and
Product ID
Indicates the Vendor Identification and Product
Identification fields of the INQUIRY command
Response Data.
Table 2-87
Buffer Access Mode and ID
Buffer Type
Buffer ID
Mode
Buffer RAM
0
0
Download Microcode
1
4
Serial Number and Manufacturing Date
4
1
Customer and Product ID
15
1
Table 2-88
Mode Descriptions (For 2.6 Gbyte Capacity Drives Only)
Mode
Description
1
Vendor specific
4
Download microcode
0
Data retained for subsequent read buffer command
Содержание SureStore Optical 2600fx
Страница 1: ...optical drive and library SCSI 2 command reference for models fx ex and mx ...
Страница 11: ...Contents x ...
Страница 20: ...Chapter 1 1 1 SCSI Command Overview 1 SCSI Command Overview ...
Страница 38: ...Chapter 2 2 1 Drive Commands SCSI 2 Drive Commands 2 SCSI 2 Drive Command Set ...
Страница 187: ...SCSI 2 Drive Command Set Write Long Command DFH Chapter 2 2 150 ...
Страница 188: ...Chapter 3 3 1 Jukebox SCSI 2 Commands 3 Jukebox SCSI 2 Command Set ...
Страница 264: ...Appendix A A 1 Drive Error Codes A Drive Error Codes ...
Страница 287: ...Drive Error Codes DSP Error Codes Appendix A A 24 ...
Страница 288: ...Appendix B B 1 Autochanger Error Codes B Autochanger Error Codes ...
Страница 339: ...Autochanger Error Codes Jukebox Micro Move Error Codes Appendix B B 52 ...
Страница 340: ...Appendix C C 1 Field Replaceable Units C Field Replaceable Units FRUs ...
Страница 345: ...Field Replaceable Units FRUs HP Field Replaceable Units FRUs Appendix C C 6 ...
Страница 346: ...Appendix D D 1 Micro Macro Moves D Micro Macro Moves ...
Страница 369: ...Micro Macro Moves HP Surestore Optical Micro Move IDs Appendix D D 24 ...
Страница 370: ...Appendix E E 1 Disconnect Timeouts E Disconnect Timeout Settings ...
Страница 373: ...Disconnect Timeout Settings Disconnect Timeout Settings Appendix E E 4 ...
Страница 377: ...Index 4 ...
Страница 378: ...Copyright 2001 Hewlett Packard Company Printed in U S A Edition 12 2001 www hp com go support Printed on recycled paper ...