Go to
Hardware — MSA — Enclosure — Hard Disk
to get the details for the device. You can
use the
Beacon LED On
button on this page to turn the LED on the front of the disk on, which
makes it easier to identify and replace.
NOTE:
If the disk is in the server node, its details are on one of the Physical Disk pages in
Hardware — Couplet — <Node> — <Node> Disk Controller
. There are no buttons on this
page.
Possible RAID states reported on the Hardware Problem Report
CRIT: The raid set is online, however some disks are down and the vdisk is not fault-tolerant
FTDN: The raid set is online and fault-tolerant, however some of the disks are down
FTOL: The raid set is online and fault tolerant
OFFL: The raid set is offline because it using offline initialization, or because disks are down and
data may be lost
QTCR: The raid set is in a critical state and has been quarantined because some disks are missing
QTOF: The raid set is offline and has been quarantined because some disks are missing
UNKN: The raid set is shutdown (stopped)
UP: The raid set is online and does not have fault-tolerant attributes
134
Troubleshooting