78
Installation
Step 9: Verify Devices on the Host
On the host system run IOSCAN (ioscan -f) and verify that the disks and LCC(s)
are listed in IOSCAN output. If the displayed “S/W State” is not “claimed,”
begin troubleshooting (see chapter 4).
Sample IOSCAN
Each LCC (
ctl
) or disk appears as a separate target in IOSCAN output.
Class I H/W Path Driver S/W State H/W Type Description
==============================================================================================
fc 0 0/4/0/0 fcT1 CLAIMED INTERFACE HP Fibre Channel Mass Storage
Adapter
lan 1 0/4/0/0.5 fcT1_cntl CLAIMED INTERFACE HP Fibre Channel Mass Storage
Cntl
fcp 0 0/4/0/0.8 fcp CLAIMED INTERFACE FCP Protocol Adapter
ba 4 0/5 lba CLAIMED BUS_NEXUS Local PCI Bus Adapter (782)
lan 2 0/5/0/0 btlan5 CLAIMED INTERFACE PCI Ethernet (10110019)
ba 5 0/8 lba CLAIMED BUS_NEXUS Local PCI Bus Adapter (782)
fc 4 0/8/0/0 td CLAIMED INTERFACE HP Tachyon TL/TS Fibre Channel
Mass Storage Adapter
fcp 4 0/8/0/0.8 fcp CLAIMED INTERFACE FCP Protocol Adapter
ext_bus 10 0/8/0/0.8.0.255.0 fcpdev CLAIMED INTERFACE FCP Device Interface
target 5 0/8/0/0.8.0.255.0.0 tgt CLAIMED DEVICE
disk 140 0/8/0/0.8.0.255.0.0.0 sdisk CLAIMED DEVICE HP 18.2GST318451FC
target 6 0/8/0/0.8.0.255.0.1 tgt CLAIMED DEVICE
disk 141 0/8/0/0.8.0.255.0.1.0 sdisk CLAIMED DEVICE HP 18.2GST318451FC
target 7 0/8/0/0.8.0.255.0.2 tgt CLAIMED DEVICE
disk 64 0/8/0/0.8.0.255.0.2.0 sdisk CLAIMED DEVICE HP 18.2GST318451FC
target 8 0/8/0/0.8.0.255.0.3 tgt CLAIMED DEVICE
disk 65 0/8/0/0.8.0.255.0.3.0 sdisk CLAIMED DEVICE HP 18.2GST318451FC
target 9 0/8/0/0.8.0.255.0.4 tgt CLAIMED DEVICE
disk 142 0/8/0/0.8.0.255.0.4.0 sdisk CLAIMED DEVICE HP 36.4GST336704FC
target 10 0/8/0/0.8.0.255.0.5 tgt CLAIMED DEVICE
disk 143 0/8/0/0.8.0.255.0.5.0 sdisk CLAIMED DEVICE HP 36.4GST336704FC
target 11 0/8/0/0.8.0.255.0.6 tgt CLAIMED DEVICE
disk 144 0/8/0/0.8.0.255.0.6.0 sdisk CLAIMED DEVICE HP 36.4GST336704FC
target 12 0/8/0/0.8.0.255.0.7 tgt CLAIMED DEVICE
Содержание StorageWorks 2405 - Disk System
Страница 1: ...hp StorageWorks disk system 2405 Edition E0902 user s guide ...
Страница 3: ...Revision History First Edition March 2002 Second Edition June 2002 Third Edition Sept 2002 ...
Страница 4: ......
Страница 12: ...12 ...
Страница 14: ......
Страница 18: ......
Страница 30: ...30 Product Description ...
Страница 35: ......
Страница 36: ......
Страница 40: ...40 Installation 3 If a part is missing contact an HP sales representative ...
Страница 44: ......
Страница 47: ...Installation 47 Installation ...
Страница 51: ......
Страница 54: ...54 Installation 9 Tighten the storage device retention M5 screws through the retention bracket see Figure 28 ...
Страница 55: ...Installation 55 Installation 10 Install a filler panel in the space below the storage device ...
Страница 57: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 70: ......
Страница 71: ......
Страница 73: ......
Страница 74: ......
Страница 77: ......
Страница 80: ...80 Installation ...
Страница 108: ...108 Troubleshooting ...
Страница 128: ......
Страница 138: ...138 Reference E VCCI Statement Japan Harmonics Conformance Japan F BSMI EMC Statement Taiwan ...
Страница 139: ...Reference 139 Reference G Declaration of Conformity ...