To perform a restart
1.
In the Configuration View panel, right-click the local system and select Configuration > Shut Down or
Restart Controller.
2.
In the main panel, set the options:
• Select the
Restart
operation.
• Select the type of controller processor to restart.
• Select whether to restart the processor in controller A, B, or both.
3.
Click
Restart
now. A confirmation dialog appears.
4.
Click
Yes
to continue; otherwise, click
No
. If you clicked Yes, a second confirmation dialog appears.
5.
Click
Yes
to continue; otherwise, click
No
. If you clicked Yes, a message describes restart activity.
NOTE:
If an iSCSI port is connected to a Microsoft Windows host, the following event is recorded
in the Windows event log:
A connection to the target was lost, but Initiator
successfully reconnected to the target
.
Shutting down
Shutting down the Storage Controller in a controller module ensures that a proper failover sequence is
used, which includes stopping all I/O operations and writing any data in write cache to disk. If the
Storage Controller in both controller modules is shut down, hosts cannot access the system's data. Perform
a shut down before removing a controller module or powering down the system.
CAUTION:
You can continue to use the CLI when either or both Storage Controllers are shut down, but
information shown might be invalid.
To perform a shut down
1.
In the Configuration View panel, right-click the local system and select
Configuration > Shut Down or
Restart Controller
.
2.
In the main panel, set the options:
• Select the
Shut down
operation.
• Select whether to restart the processor in controller A, B, or both.
3.
Click
Shut down now
. A confirmation dialog appears.
4.
Click
Yes
to continue; otherwise, click
No
. If you clicked Yes, a second confirmation dialog appears.
5.
Click
Yes
to continue; otherwise, click
No
. If you clicked Yes, a message describes shutdown activity.
NOTE:
If an iSCSI port is connected to a Microsoft Windows host, the following event is recorded
in the Windows event log:
Initiator failed to connect to the target
.
Содержание StorageWorks 2000i
Страница 8: ...8 ...
Страница 10: ...10 ...
Страница 28: ...28 Getting started ...
Страница 66: ...66 Using system tools ...
Страница 76: ...76 Viewing system status ...
Страница 88: ...88 SNMP reference ...
Страница 106: ...106 Event code reference ...
Страница 112: ...112 Using FTP to download logs and update firmware ...