Removal and replacement procedures 37
For more information about battery replacement or proper disposal, contact an authorized reseller or an
authorized service provider.
Flash-backed write cache procedures
The following types of procedures are provided for the FBWC option:
•
Removal and replacement of failed components:
o
Removing the cache module ("
" on page
o
Removing the capacitor pack ("
" on page
o
Removing the capacitor pack holder ("
" on page
CAUTION:
Do not detach the cable that connects the battery pack or capacitor pack to the cache
module. Detaching the cable causes all data in the cache module to be lost.
FBWC module
CAUTION:
The cache module connector does not use the industry-standard DDR3 mini-DIMMs.
Do not use the controller with cache modules designed for other controller models, because the
controller can malfunction and you can lose data. Also, do not transfer this cache module to an
unsupported controller model, because you can lose data.
CAUTION:
In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the drives as failed when the server is powered up.
To remove the component:
1.
Power down the server (on page
2.
Disconnect all peripheral cables from the server.
3.
Remove the server from the chassis (on page
4.
Remove the front GPU cage (on page
5.
Remove the interposer board assembly (on page
6.
Remove the front GPU bracket (on page
7.
Remove the SFF hot-plug drive cage (on page
8.
Remove the PCI riser cage (on page
CAUTION:
When connecting or disconnecting the capacitor pack cable, the connectors on the
cache module and cable are susceptible to damage. Avoid excessive force and use caution to
avoid damage to these connectors.
Содержание ProLiant SL250s Gen8
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 72: ...Component identification 72 Item LED Status Definition Off The drive is not configured by a RAID controller ...
Страница 74: ...Cabling 74 SFF hot plug drive cage Front quick release cage Left node ...
Страница 75: ...Cabling 75 Right node Rear quick release drive cage Left node ...
Страница 78: ...Cabling 78 Mini SAS cabling SFF hot plug drive cage Front quick release drive cage Left node ...
Страница 79: ...Cabling 79 Right node Rear quick release drive cage Left node ...
Страница 80: ...Cabling 80 Right node FBWC capacitor pack cabling Left node ...
Страница 81: ...Cabling 81 Right node ...