Removal and replacement procedures 24
•
Remove the server from the chassis (on page
If the rack environment, cabling configuration, or the server location in the rack creates unstable
conditions, then remove the server from the chassis.
•
Remove the SFF hot-plug drive cage (on page
•
Remove the front GPU cage (on page
•
Remove the interposer board ("
Remove the interposer board assembly
" on page
•
Remove the front GPU bracket (on page
•
Remove the PCI riser cage (on page
•
Remove the FlexibleLOM riser cage (on page
•
Remove the rear GPU cage (on page
Power down the server
Before powering down the server for any upgrade or maintenance procedures, perform a backup of critical
server data and programs.
IMPORTANT:
When the server is in standby mode, auxiliary power is still being provided to the
system.
To power down the server, use one of the following methods:
•
Press and release the Power On/Standby button.
This method initiates a controlled shutdown of applications and the OS before the server enters standby
mode.
•
Press and hold the Power On/Standby button for more than 4 seconds to force the server to enter
standby mode.
This method forces the server to enter standby mode without properly exiting applications and the OS.
If an application stops responding, you can use this method to force a shutdown.
•
Use a virtual power button selection through iLO 4.
This method initiates a controlled remote shutdown of applications and the OS before the server enters
standby mode.
Before proceeding, verify the server is in standby mode by observing that the system power LED is amber.
Remove the server from the chassis
1.
Power down the server (on page
2.
Disconnect all peripheral cables from the server.
CAUTION:
To avoid damage to the server, always support the bottom of the server when
removing it from the chassis.
3.
Remove the server from the chassis:
a.
Press the release button on the front of the server, and then extend the tray handle.
b.
Press the release button on the side of the server.
Содержание ProLiant SL250s Gen8
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 72: ...Component identification 72 Item LED Status Definition Off The drive is not configured by a RAID controller ...
Страница 74: ...Cabling 74 SFF hot plug drive cage Front quick release cage Left node ...
Страница 75: ...Cabling 75 Right node Rear quick release drive cage Left node ...
Страница 78: ...Cabling 78 Mini SAS cabling SFF hot plug drive cage Front quick release drive cage Left node ...
Страница 79: ...Cabling 79 Right node Rear quick release drive cage Left node ...
Страница 80: ...Cabling 80 Right node FBWC capacitor pack cabling Left node ...
Страница 81: ...Cabling 81 Right node ...