Removal and replacement procedures 58
After you replace the system board, you must re-enter the server serial number and the product ID.
1.
During the server startup sequence, press the
F9
key to access RBSU.
2.
Select the
Advanced Options
menu.
3.
Select
Service Options
.
4.
Select
Serial Number
. The following warning appears:
Warning: The serial number should ONLY be modified by qualified service
personnel. This value should always match the serial number located on the
chassis.
5.
Press the
Enter
key to clear the warning.
6.
Enter the serial number and press the
Enter
key.
7.
Select
Product ID
. The following warning appears:
Warning: The Product ID should ONLY be modified by qualified service
personnel. This value should always match the Product ID located on the
chassis.
8.
Enter the product ID and press the
Enter
key.
9.
Press the
Esc
key to close the menu.
10.
Press the
Esc
key to exit RBSU.
11.
Press the
F10
key to confirm exiting RBSU. The server automatically reboots.
Personality board
To remove the component:
1.
Power down the server (on page
2.
Disconnect all peripheral cables from the server.
3.
Remove the server from the chassis (on page
4.
Remove the front GPU cage (on page
5.
Remove the interposer board assembly (on page
6.
Remove the front GPU bracket (on page
7.
Remove the level 2 power board ("
" on page
8.
Disconnect all cables connected to the personality board.
Содержание ProLiant SL250s Gen8
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 72: ...Component identification 72 Item LED Status Definition Off The drive is not configured by a RAID controller ...
Страница 74: ...Cabling 74 SFF hot plug drive cage Front quick release cage Left node ...
Страница 75: ...Cabling 75 Right node Rear quick release drive cage Left node ...
Страница 78: ...Cabling 78 Mini SAS cabling SFF hot plug drive cage Front quick release drive cage Left node ...
Страница 79: ...Cabling 79 Right node Rear quick release drive cage Left node ...
Страница 80: ...Cabling 80 Right node FBWC capacitor pack cabling Left node ...
Страница 81: ...Cabling 81 Right node ...