Removal and replacement procedures 49
To replace the system board:
1.
Put the system board in the tray. The screw holes on the tray should align with the holes on the
system board.
2.
Fasten the screws to secure the system board to the tray.
Figure 31
Installing the system board
NOTE:
It is important to ensure the System Serial Number is updated to the original Serial Number
after replacing the system board. See the “Navigating through the Setup Utility” section on page 61
to input the correct System Serial Number and Asset Tag information. Also, you can input all the
other customer specific setup requirements that are required.
Power supply unit (PSU)
Located on the rear panel of the server power supply is a standard ranging 750 watt or 1200 watt
PSU with PFC (power factor correction) function.
NOTE:
Power supplies with different wattage cannot be mixed in the same chassis.