![HP ProLiant MicroServer Скачать руководство пользователя страница 81](http://html.mh-extra.com/html/hp/proliant-microserver/proliant-microserver_maintenance-and-service-manual_164816081.webp)
Diagnostic tools 81
Error code
Error message
Corrective action/description
017
Processor temperature out of
range
If the system detects that the processor
temperature sensor over heated, then this
message will appear.
018
NB temperature out of range
If system detects NB temperature sensor over
heat, this message will appear.
040
Refresh timer test failed
BIOS POST found that the refresh timer
hardware failed to pass the Refresh Retrace
Test.
041
Display memory test failed
Memory test failed because the memory has
an issue
043
~<INS> Pressed
If you press Insert key during POST, this
message will appear
044
DMA Controller Error
The system found some issues of the DMA
controller when performing diagnostic tests
for DMAC-1 & DMAC-2.
045
DMA-1 Error
The system found some issues of the DMA
controller when do diagnostic tests for
DMAC-1
046
DMA-2 Error
The system find some issues of the DMA
controller when do diagnostic tests for
DMAC-2
048
Password check failed
If the user inputs an incorrect password more
than three times, then this error displays
information and the system continues to boot.
05D
S.M.A.R.T. Command Failed
Hard Disk S.M.A.R.T feature test failed,
indicating an issue with the hard disk.
POST related troubleshooting
Perform the following procedures when POST fails to run or displays error messages.
If the POST failure is during a routine boot up, check the following:
•
All external cables and power cables should be firmly plugged in.
•
The power outlet to which the server is connected and is working.
•
The server and monitor are both turned on. The power status LED indicator on the front panel
must be lit up green.
•
The monitor's contrast and brightness settings are correct.
•
All internal cables are properly connected and all boards are firmly seated.
•
The processor is fully seated in its socket.
•
The heat sink is properly installed on top of the processor.
•
All memory modules are properly installed.
Содержание ProLiant MicroServer
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 16: ...Illustrated parts catalog 16 Illustrated parts catalog Mechanical components ...
Страница 20: ...Illustrated parts catalog 20 ...
Страница 21: ...Illustrated parts catalog 21 System components ...
Страница 38: ...Removal and replacement procedures 38 6 Perform the post installation procedure ...
Страница 50: ...Removal and replacement procedures 50 5 Perform the post installation procedure ...
Страница 63: ...Diagnostic tools 63 iii Click Choose what the power buttons do iv Choose shut down and then choose apply ...
Страница 65: ...Diagnostic tools 65 3 Click Next 4 Select I accept the terms of the license agreement and click Next ...
Страница 66: ...Diagnostic tools 66 5 Click Browse to select folder and then click Next 6 Click Next ...
Страница 67: ...Diagnostic tools 67 7 Click Install 8 Click Finish ...
Страница 69: ...Diagnostic tools 69 11 Select if remember the passwords 12 Click in front of Physical Drive View ...
Страница 70: ...Diagnostic tools 70 13 Click options Enable or Disable to change Write cache and NCQ status ...