Removal and replacement procedures 47
Fan and fan blank
Fan population guidelines
Configuration Fan bay
1
Fan bay
2
Fan bay
3
Fan bay
4
Fan bay
5
Fan bay
6
One processor,
non-redundant
Fan
Fan
Blank
Fan
Blank
Blank
One processor,
redundant
Fan
Fan
Fan
Fan
Fan
Blank
Two processors,
non-redundant
Fan
Fan
Blank
Fan
Blank
Fan
Two processors,
redundant
Fan
Fan
Fan
Fan
Fan
Fan
•
In the redundant fan mode:
o
If one fan rotor fails, the system continues to operate without redundancy. This condition is
indicated by a flashing amber Health LED.
o
If two fan rotors fail, the operating system shuts down.
Fan blank
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, take the appropriate anti-static
precautions before beginning any system installation. Improper grounding can cause
electrostatic discharge.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the chassis
unless all bays are populated with a component or a blank.
To remove the component:
1.
Power down the server (on page
Содержание ProLiant DL60 Gen9
Страница 5: ...Contents 5 Documentation feedback 111 Index 112 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 23: ...Illustrated parts catalog 23 ...
Страница 33: ...Removal and replacement procedures 33 o Secondary PCI riser cage o PCI blank ...
Страница 95: ...Component identification 95 Fan locations ...
Страница 100: ...Cabling 100 FBWC module slot 3 cabling M 2 SSD cabling Slot 2 cable routing 2 ports supported when slot 1 is unoccupied ...
Страница 110: ...Acronyms and abbreviations 110 UID unit identification USB universal serial bus ...