Specifications 100
Specifications
Environmental specifications
Specification
Value
Temperature range*
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping
-40
°
C to 70
°
C (-40
°
F to 158
°
F)
Maximum wet bulb temperature 28
°
C (82.4
°
F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Nonoperating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3,048 m
(10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.
Mechanical specifications
Specification
Value
Height
17.5 cm (6.88 in)
Depth
73.6 cm (29 in)
Width
44.4 cm (17.48 in)
Weight (maximum)
52 kg (115 lb)
Weight (no drives installed)
33 kg (73 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
HPE 1200 W Common Slot Platinum Plus Hot-Plug Power Supply (94% efficiency) (on page
HPE 1500 W Common Slot -48 VDC Hot-plug Power Supply (on page
HPE 1500 W Common Slot Platinum Plus Hot-Plug Power Supply (94% efficiency) (on page
•
For detailed power supply specifications, see the server QuickSpecs on the Hewlett Packard
HPE 1200 W Common Slot Platinum Plus Hot-Plug Power
Supply (94% efficiency)
Specification
Value
Input requirements
Rated input voltage
100 VAC,100 to 120 VAC
Содержание ProLiant DL580 Gen9
Страница 5: ...Contents 5 Documentation feedback 106 Index 107 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 98: ...Cabling 98 Front video USB cabling Power supply data cabling ...
Страница 99: ...Cabling 99 Standby power cabling Systems Insight Display cabling ...