![HP ProLiant DL320 Generation 5p Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/hp/proliant-dl320-generation-5p/proliant-dl320-generation-5p_user-manual_164689016.webp)
Component identification 16
NMI functionality
An NMI crash dump enables administrators to create crash dump files when a system is hung and not
responding to traditional debug mechanisms.
Crash dump log analysis is an essential part of diagnosing reliability problems, such as hangs in
operating systems, device drivers, and applications. Many crashes freeze a system, and the only
available action for administrators is to cycle the system power. Resetting the system erases any
information that could support problem analysis, but the NMI feature preserves that information by
performing a memory dump before a hard reset.
To force the OS to invoke the NMI handler and generate a crash dump log, the administrator can do any
of the following:
•
Short the NMI jumper pins
•
Press the NMI switch
•
Use the iLO Virtual NMI feature
For additional information, see the whitepaper on the HP website
(
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00797875/c00797875.pdf
).
System board LEDs
Item LED
description Status
1
Processor error
Amber = A multibit error has occurred.
Off = Normal
2
PPM failure
Amber = PPM has failed.
Off = Normal
3
Fan 1 failure
Amber = Fan 1 has failed or is missing.
Off = Normal
Содержание ProLiant DL320 Generation 5p
Страница 1: ...HP ProLiant DL320 Generation 5p Server User Guide Part Number 451883 003 October 2008 Third Edition ...
Страница 19: ...Component identification 19 Fan locations Standard configurations include either three or four fans ...
Страница 23: ...Operations 23 4 Install the server into the rack ...
Страница 55: ...Cabling 55 Optional internal USB cabling ...
Страница 75: ...Troubleshooting 75 ...
Страница 99: ...Technical support 99 ...
Страница 100: ...Technical support 100 ...