Hardware options installation 33
•
Drives must be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.
Optional storage controllers provide support for hot-plug capability and drive LEDs. Controller options
are:
•
The embedded controller supports non-hot-plug SATA hard drives. Drive LEDs are not supported.
•
Optional SATA controllers support hot-plug SATA hard drives and drive LEDs.
•
Optional SAS controllers support hot-plug SAS or SATA hard drives and drive LEDs.
Removing a hard drive blank
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
Remove the component as indicated.
Removing a hard drive
IMPORTANT:
Hot-plug capability and drive LED support are only available when a supported
optional controller is installed in the server.
To remove the component:
1.
Back up all data on the hard drive.
2.
Power down the server (on page
16
).
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.