Removal and replacement procedures 87
Figure 82
System Fan Connections
Device number
Connector
System fan 1
J63 on the system board
System fan 2
J71 on the system board
System fan 3
J62 on the system board
System fan 4
(optional)
J70 on the system board
System fan 5
J68 on the system board
System fan 6
J67 on the system board
A new system fan can be installed to allow the server to operate properly in case a default system fan
becomes defective.
To remove the system fan:
1.
Power down the server.
2.
Disconnect the power cord(s).
3.
Unlock the server if necessary and remove the top cover as described in the section “System
cover”.
4.
Disconnect the system fan cable from its corresponding board connector.
5.
Release the fan cable from the cable clip securing it to the chassis partition wall.
6.
Lift the system fan away from the chassis.