Diagnostic tools and setup utilities 109
BIOS update
HP recommends that you update the server BIOS with the latest system BIOS version to take
advantage of the most recent compatibility fixes. The latest BIOS version for your server can be
downloaded from http://www.hp.com.
Clear CMOS
You may need to clear the Setup configuration values (CMOS) if the configuration has been
corrupted, or if incorrect settings made in the Setup Utility have caused error messages to be
unreadable.
To clear CMOS:
1.
Perform the Pre-installation procedure.
2.
If necessary, remove any accessory boards or cables that prevent access to the system
configuration switch.
3.
Locate the system maintenance jumper (J27) on the system board.
4.
Press the button. AC power must not be connected.
5.
Perform the Post-installation instructions.
6.
During POST, press
F10
to access the Setup Utility.
7.
Load setup defaults by pressing
F9
.
8.
Set time, date, and other system values.
9.
Press
F10
to close the Setup Utility.
NOTE:
Clearing CMOS restore all system configurations and password default settings.
Power-On Self-Test (POST)
Before you can use a server, all devices must be tested and initialized, and the operating system must
be bootstrapped to the memory. This is referred to as Power–On Self-Test or POST. POST is a series of
diagnostic tests that checks firmware and hardware components on the system to ensure that the
server is properly functioning. This diagnostic function automatically runs each time the server is
powered on.
These diagnostics, which reside in the BIOS ROM, isolate server-related logic failures and indicate the
board or component that you need to replace, as indicated by the error messages. Most server
hardware failures will be accurately isolated during POST. The number of tests displayed depends on
the configuration of the server.
During POST you can:
•
Press
ESC
to skip the HP logo and go to POST boot progress display system summary screen.
•
Press
F10
to access the Setup Utility.
•
Press
F12
to request a network boot (PXE).
•
Press F1 to continue POST after POST errors are detected.
Содержание ProLiant DL160se - G6 Server
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 20: ...Illustrated parts catalog 20 ...
Страница 55: ...Removal and replacement procedures 55 Figure 31 Reinstalling the Backplane 3 Install all cables ...