Component identification 77
•
SFF configuration
When using the embedded Smart Array controller in an SFF configuration only drives 1, 2, 3, and 4 are
available.
Drive LED definitions
Item LED
Status
Definition
1
Locate
Solid blue
The drive is being identified by a host application.
Flashing blue
The drive carrier firmware is being updated or requires an update.
2
Activity ring
Rotating green
Drive activity
Off
No drive activity
3
Do not remove
Solid white
Do not remove the drive. Removing the drive causes one or more of
the logical drives to fail.
Off
Removing the drive does not cause a logical drive to fail.
4
Drive status
Solid green
The drive is a member of one or more logical drives.
Flashing green
The drive is rebuilding or performing a RAID migration, stripe size
migration, capacity expansion, or logical drive extension, or is
erasing.
Flashing
amber/green
The drive is a member of one or more logical drives and predicts
the drive will fail.
Flashing amber The drive is not configured and predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID controller.
FBWC module LED definitions
The FBWC module has three single-color LEDs (one amber and two green). The LEDs on the cache module
installed on a storage controller are duplicated on the reverse side of the module to facilitate status viewing.