Removal and replacement procedures 65
c.
Finish the installation by completely tightening the screws in the same sequence.
11.
Install all components removed from the failed system board.
IMPORTANT:
Install all components with the same configuration that was used on the failed
system board.
12.
Install the fans and connect the fan cables to the system board.
13.
Connect all cables disconnected from the failed system board.
14.
Install the processor air baffle.
15.
Install the access panel.
16.
Do one of the following:
o
Slide the server into the rack.
o
Install the server into the rack.
17.
Connect each power cord to the server.
18.
Connect each power cord to the power source.
19.
Power up the server.
After you replace the system board, you must re-enter the server serial number and the product ID.
1.
During the server startup sequence, press the
F9
key to access RBSU.
2.
Select the
Advanced Options
menu.
3.
Select
Service Options
.
4.
Select
Serial Number
. The following warnings appear:
WARNING! WARNING! WARNING! The serial number is loaded into the system during
the manufacturing process and should NOT be modified. This option should only
be used by qualified service personnel. This value should always match the
serial number sticker located on the chassis.
Warning: The serial number should ONLY be modified by qualified personnel.
This value should always match the serial number located on the chassis.
5.
Press the
Enter
key to clear the warning.
6.
Enter the serial number and press the
Enter
key.