Battery replacement 66
Battery replacement
HP recommends replacing the battery on both server A and server B when either battery is replaced.
If the server blade no longer automatically displays the correct date and time, you may need to replace
the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.
WARNING:
The computer contains an internal lithium manganese dioxide, a vanadium
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
•
Do not attempt to recharge the battery.
•
Do not expose the battery to temperatures higher than 60°C (140°F).
•
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
•
Replace only with the spare designated for this product.
To remove the component:
1.
Power down the server blade (on page 11).
2.
Remove the server blade (on page 12).
3.
Access the internal server components (on page 12).
4.
Identify the battery location ("System board components" on page 7).
5.
Remove the battery.
IMPORTANT:
Replacing the system board battery resets the system ROM to its default
configuration. After replacing the battery, reconfigure the system through RBSU.
To replace the component, reverse the removal procedure.
Содержание PROLIANT 580554-001
Страница 1: ...HP ProLiant BL2x220c G6 Server Blade User Guide Part Number 580554 001 November 2009 First Edition ...
Страница 17: ...Setup 17 1 Remove the device bay blank 2 Remove the enclosure connector cover 3 Install the server blade ...
Страница 81: ...Technical support 81 ...
Страница 82: ...Technical support 82 ...
Страница 84: ...Acronyms and abbreviations 84 UID unit identification USB universal serial bus ...