Component identification 10
System maintenance switch
Position Function
Default
1
iLO 2 security override
Off
2 Configuration
lock
Off
3 Reserved
Off
4 Reserved
Off
5 Password
disabled
Off
6 Reset
configuration
Off
7 Reserved
Off
8 Reserved
Off
When the system maintenance switch position 6 is set to the On position, the system is prepared to erase
all system configuration settings from both CMOS and NVRAM.
CAUTION:
Clearing CMOS and/or NVRAM deletes configuration information. Be sure to
properly configure the server or data loss could occur.
Access components
CAUTION:
The jackscrews control the unseating and seating of critical system connectors.
Failure to use the jackscrews to remove and install the server B assembly can cause the system
boards to fail.
Item Description
1 Jackscrew
1
2 Jackscrew
2
3
T-15 Torx wrench