Software and configuration utilities 40
6.
Press the
Enter
key.
7.
Press the
Esc
key to exit the current menu or press the
F10
key to exit RBSU.
For more information on mirrored memory, see the white paper on the HP website
(http://h18000.www1.hp.com/products/servers/technology/memoryprotection.html).
Configuring lockstep memory
To configure Lockstep memory:
1.
Install the required DIMMs.
2.
Access RBSU by pressing the
F9
key during power-up when the prompt is displayed.
3.
Select
System Options
.
4.
Select
Advanced Memory Protection
.
5.
Select
Lockstep with Advanced ECC Support
.
6.
Press the
Enter
key.
7.
Press the
Esc
key to exit the current menu, or press the
F10
key to exit RBSU.
For more information on Lockstep memory, see the white paper on the HP website
(http://h18000.www1.hp.com/products/servers/technology/memoryprotection.html).
Array Configuration Utility
ACU is a browser-based utility with the following features:
•
Runs as a local application or remote service
•
Supports online array capacity expansion, logical drive extension, assignment of online spares, and
RAID or stripe size migration
•
Suggests the optimum configuration for an unconfigured system
•
Provides different operating modes, enabling faster configuration or greater control over the
configuration options
•
Remains available any time that the server is on
•
Displays on-screen tips for individual steps of a configuration procedure
For optimum performance, the minimum display settings are 800 × 600 resolution and 256 colors.
Servers running Microsoft® operating systems require Internet Explorer 5.5 (with Service Pack 1) or later.
For Linux servers, refer to the README.TXT file for additional browser and support information.
For more information, refer to the
Configuring Arrays on HP Smart Array Controllers Reference Guide
on
the Documentation CD or the HP website (http://www.hp.com).
Option ROM Configuration for Arrays
Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign
RAID levels, and establish online spare configurations.
The utility also provides support for the following functions:
•
Reconfiguring one or more logical drives
•
Viewing the current logical drive configuration
Содержание PROLIANT 580554-001
Страница 1: ...HP ProLiant BL2x220c G6 Server Blade User Guide Part Number 580554 001 November 2009 First Edition ...
Страница 17: ...Setup 17 1 Remove the device bay blank 2 Remove the enclosure connector cover 3 Install the server blade ...
Страница 81: ...Technical support 81 ...
Страница 82: ...Technical support 82 ...
Страница 84: ...Acronyms and abbreviations 84 UID unit identification USB universal serial bus ...