Operations 13
2.
Remove the server blade (on page 12).
3.
Place the server blade on a flat, level work surface with the bezel facing away from you.
CAUTION:
The jackscrews control the unseating and seating of critical system connectors.
Failure to use the jackscrews to remove and install the server B assembly can cause the system
boards to fail.
4.
Turn jackscrew 1 approximately six turns counterclockwise.
5.
Turn jackscrew 2 counterclockwise until the threads are fully disengaged.
6.
Turn jackscrew 1 counterclockwise until the threads are fully disengaged.
CAUTION:
To prevent damage to the server blade, do not apply pressure to the enclosure
connector.
7.
Lift the server B assembly from the server A assembly, and then place it on the work surface with the
system board facing up.
Install the server B assembly
For access component identification, see "Access components (on page 10)."
1.
Engage the front edge of the server B assembly with the front edge of the server A assembly.
CAUTION:
To avoid possible damage to mezzanine card cables, route any cables so that
they do not become pinched when the server B assembly is installed.
IMPORTANT:
To avoid possible damage to the serial label pull tab, extend the serial label
pull tab approximately 1 cm (0.4 in) before installing the server B assembly on the server A
assembly.
2.
Lower the server B assembly onto the server A assembly.
3.
Align the signal and power connectors on the server B assembly with the corresponding connectors
on the server A assembly.
Содержание PROLIANT 580554-001
Страница 1: ...HP ProLiant BL2x220c G6 Server Blade User Guide Part Number 580554 001 November 2009 First Edition ...
Страница 17: ...Setup 17 1 Remove the device bay blank 2 Remove the enclosure connector cover 3 Install the server blade ...
Страница 81: ...Technical support 81 ...
Страница 82: ...Technical support 82 ...
Страница 84: ...Acronyms and abbreviations 84 UID unit identification USB universal serial bus ...