Installing the Switch
Installation Procedures
Flat Wall Mounting
You can mount the Non-PWR switches on a wall as shown in the illustration
on the next page. However, this is not supported for the 2626-PWR or the 2650
PWR switches. Wall mounting the PWR switches is not supported because of
the size and weight of the devices. Wall mounting the 2600-8-PWR switch is
supported. See
for instructions.
W A R N I N G
For safe operation do not install the switch with the back face of the
switch (with the fan vents) facing either downward or upward. Do not
wall mount the 2626-PWR or the 2650-PWR switches.
C a u t i o n
The switch should be mounted only to a wall or wood surface that is at least
1/2-inch (12.7 mm) plywood or its equivalent.
Supported Wall Mounting Positions.
Switch
Vertical Wall Mounting
Horizontal Wall Mounting
2626 Non-PWR
Yes
No
2650 Non-PWR
Yes
No
2626-PWR
No
No
2650-PWR
No
No
2600-8-PWR
No
Yes
2-16