Important
Caution
Hardware Installation
Installing RF Security Sensors
Power
Ethernet
Radio
Description
Slow blink
Green
Slow Blink
Any
The Sensor is unable to connect to the RF Manager Server.
Slow blink
Green
Any
Solid Green
There is an error on 802.11a/b/g interfaces.
Slow blink
Green
Any
Any
The Sensor is experiencing a software error.
Off
Off
Off
The Sensor is not powered on or it is in the process of starting
up.
Installing RF Security Sensors
To prevent abuse and intrusion by unauthorized personnel, it is extremely important to install
Sensors such that it is difficult to unplug the devices from the network or from the power outlet.
For information on how to install the MSM325 Sensor or MSM320 with Sensor license, see the
MSM320 Quickstart. For controlled-mode operation, follow the directions through the end of the
Installation section. For autonomous-mode operation, follow the directions through step D of the
Initial Configuration procedure.
For information on how to install the MSM335 Sensor see the MSM335 Quickstart. For controlled-
mode operation, follow the directions through the end of the Installation section. For
autonomous-mode operation, follow the directions through step D of the Initial Configuration
procedure.
Installing the MSM415 Sensor
Professional Installation Required
Prior to installing or using the MSM415, consult with a professional installer trained in RF
installation and knowledgeable in local regulations including building and wiring codes, safety,
channel, power, indoor/outdoor restrictions, and license requirements for the intended country. It
is the responsibility of the end user to ensure that installation and use comply with local safety
and radio regulations.
Cabling
: You must use the appropriate cables, and where applicable, surge protection, for your
given region. For compliance with EN55022 Class-B emissions requirements use shielded Ethernet
cables. Cables with large boots may not insert into the RJ-45 connectors properly. It is recommended
that you do not use such cables.
Plenum installation:
The MSM415 and appropriate cabling can be installed in a plenum (UL2043
rating). The MSM415 should be installed with its top surface facing the floor (similar orientation as
in a ceiling installation). However, it is left to a qualified installer to determine how to install/secure
the MSM415 in a plenum in an appropriate and safe manner. Plenum-rated cables and attachment
hardware must be used.
Safety:
Take note of the following safety information during installation.
If your network covers an area served by more than one power distribution system, be sure all
safety grounds are securely interconnected.
1-11
Содержание MSM415
Страница 2: ......
Страница 3: ...HP ProCurve RF Manager and Sensors Installation and Getting Started Guide ...
Страница 20: ...Hardware Installation Installing RF Security Sensors 1 14 ...
Страница 40: ...Safety and Regulatory Information for RF Manager Controller Taiwan A 8 ...
Страница 46: ...Regulatory information for MSM415 RF Security Sensor Notice for Korea B 6 ...
Страница 47: ...Appendix C RoHS and Waste Information C RoHS and Waste Information China Information ...
Страница 51: ......