48
Connecting to the controller CLI port
set network-parameters ip
address
netmask
netmask
gateway
gateway
controller a|b
where:
•
address
is the IP address of the controller
•
netmask
is the subnet mask
•
gateway
is the IP address of the subnet router
•
a|b
specifies the controller whose network parameters you are setting
For example:
# set network-parameters ip 192.168.0.10 netmask 255.255.255.0 gateway
192.168.0.1 controller a
# set network-parameters ip 192.168.0.11 netmask 255.255.255.0 gateway
192.168.0.1 controller b
8.
Type the following command to verify the new IP addresses:
show network-parameters
Network parameters, including the IP address, subnet mask, and gateway address are displayed for
each controller.
9.
Use the
ping
command to verify network connectivity.
For example:
# ping 192.168.0.1 (gateway)
Info: Pinging 192.168.0.1 with 4 packets.
Success: Command completed successfully. - The remote computer responded with 4
packets.
10.
In the host computer's command window, type the following command to verify connectivity, first for
controller A and then for controller B:
ping controller-
IP-address
If you cannot access your system for at least three minutes after changing the IP address, your network
might require you to restart the Management Controller(s) using the CLI. When you restart a
Management Controller, communication with it is temporarily lost until it successfully restarts.
Type the following command to restart the management controller on both controllers:
restart mc both
11.
When you are done using the CLI, exit the emulator.
12.
Retain the new IP addresses to access and manage the controllers, using either the SMU or the CLI.
NOTE:
Using HyperTerminal with the CLI on a
Microsoft Windows
host:
On a host computer connected to a controller module’s mini-USB CLI port, incorrect command syntax in a
HyperTerminal session can cause the CLI to hang. To avoid this problem, use correct syntax, use a different
terminal emulator, or connect to the CLI using telnet rather than the mini-USB cable.
Be sure to close the HyperTerminal session before shutting down the controller or restarting its Management
Controller. Otherwise, the host’s CPU cycles may rise unacceptably.
If communication with the CLI is disrupted when using an out-of-band cable connection, communication
can sometimes be restored by disconnecting and reattaching the mini-USB cable as described in
page 46.
The USB device driver is also available from the Software Support and Documentation CD
that shipped
with your product.
NOTE:
Access the download from your HP MSA support website at
http://www.hp.com/support
.
Содержание MSA 2040
Страница 8: ...8 Figures ...
Страница 10: ...10 Tables ...
Страница 32: ...32 Installing the enclosures ...
Страница 44: ...44 Connecting hosts ...
Страница 50: ...50 Connecting to the controller CLI port ...
Страница 52: ...52 Basic operation ...
Страница 70: ...70 Troubleshooting ...
Страница 74: ...74 Support and other resources ...
Страница 76: ...76 Documentation feedback ...
Страница 88: ...88 LED descriptions ...
Страница 94: ...94 Electrostatic discharge ...
Страница 100: ...100 Index ...