Removal and replacement procedures  35 

6.

 

Remove the fan.  

 

To replace the component, reverse the removal procedure. 

 

Expansion slot cover 

To remove the component: 

1.

 

Do one of the following: 

 

Unlock and remove the bezel ("

Front bezel

" on page 

27

). 

 

Extend the server from the rack (on page 

26

). 

2.

 

Remove the access panel ("

Access panel

" on page 

29

). 

3.

 

Push the release latches on the expansion board retainer and open the retainer. 

 

Содержание ML350 - ProLiant - G2

Страница 1: ...HP ProLiant ML350 Generation 5 Server Maintenance and Service Guide June 2006 First Edition Part Number 405046 001 ...

Страница 2: ...are U S registered trademarks of Microsoft Corporation Windows Server 2003 is a trademark of Microsoft Corporation Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a U S registered trademark of Linus Torvalds June 2006 First Edition Part Number 405046 001 Audience assumptions This guide is for an exper...

Страница 3: ...ccess panel 29 Rack bezel 29 Rack rails 30 Power supply blank 31 Hot plug power supply 31 Hard drive blanks 32 Hot plug SATA and SAS hard drives 33 Air baffle 33 System fans 34 Expansion slot cover 35 Expansion board 36 Media bay blank 37 Half height or full height media device 38 Heatsink 39 Processor 41 PPM 46 FBDIMM 47 Parallel and second serial connector 48 Battery 49 System board 50 Power sup...

Страница 4: ...anel LEDs and buttons 61 Rear panel components 62 Rear panel LEDs and buttons 63 System board components 64 NMI jumper 65 System maintenance switch 65 System board LEDs 66 System LEDs and internal health LED combinations 67 SAS and SATA hard drive LEDs 68 SAS and SATA hard drive LED combinations 68 Specifications 70 Environmental specifications 70 Server specifications 70 Rack server specification...

Страница 5: ...n will help you over the telephone HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP In cases where it is required to return the defective part to HP you must ship the defective part back to HP within a defined period of time normally five 5 business days The defective part must be returned with the associated documentation in the pro...

Страница 6: ...ine la société de courses ou le transporteur à utiliser Pour plus d informations sur le programme CSR de HP contactez votre Mainteneur Agrée local Pour plus d informations sur ce programme en Amérique du Nord consultez le site Web HP http www hp com go selfrepair Service de garantie pièces seules Votre garantie limitée HP peut inclure un service de garantie pièces seules Dans ce cas les pièces de ...

Страница 7: ...imieren und höhere Flexibilität beim Austausch defekter Bauteile zu ermöglichen Wenn HP oder ein HP Servicepartner bei der Diagnose feststellt dass das Produkt mithilfe eines CSR Teils repariert werden kann sendet Ihnen HP dieses Bauteil zum Austausch direkt zu CSR Teile werden in zwei Kategorien unterteilt Zwingend Teile für die das Customer Self Repair Verfahren zwingend vorgegeben ist Wenn Sie ...

Страница 8: ...rgo de los gastos de desplazamiento y de mano de obra de dicho servicio Opcional componentes para los que la reparación por parte del usuario es opcional Estos componentes también están diseñados para que puedan ser reparados por el usuario Sin embargo si precisa que HP realice su sustitución puede o no conllevar costes adicionales dependiendo del tipo de servicio de garantía correspondiente al pr...

Страница 9: ...eparatie door de klant optioneel is Ook deze onderdelen zijn ontworpen voor reparatie door de klant Als u echter HP verzoekt deze onderdelen voor u te vervangen kunnen daarvoor extra kosten in rekening worden gebracht afhankelijk van het type garantieservice voor het product OPMERKING Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant In verband met de garantievoorwaarden moet...

Страница 10: ...a HP exige que um técnico autorizado substitua a peça Essas peças estão identificadas com a marca No Não no catálogo de peças ilustrado Conforme a disponibilidade e o local geográfico as peças CSR serão enviadas no primeiro dia útil após o pedido Onde as condições geográficas permitirem a entrega no mesmo dia ou em quatro horas pode ser feita mediante uma taxa adicional Se precisar de auxílio entr...

Страница 11: ...Customer self repair 11 ...

Страница 12: ...Customer self repair 12 ...

Страница 13: ...Customer self repair 13 ...

Страница 14: ...Customer self repair 14 ...

Страница 15: ...ted parts catalog In this section Mechanical components 15 System components 19 Mechanical components Item Description Spare part number Customer self repair on page 5 1 Access panel 413981 001 Mandatory1 2 Rack bezel 413983 001 Mandatory1 ...

Страница 16: ...licable à votre produit 3 No Non Certaines pièces HP ne sont pas conçues pour permettre au client d effectuer lui même la réparation Pour que la garantie puisse s appliquer HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé Ces pièces sont identifiées par la mention Non dans le Catalogue illustré 1 Mandatory Obbligatorie Parti che devono essere necessariamente riparate ...

Страница 17: ...w rekening 2 Optional Optioneel Onderdelen waarvoor reparatie door de klant optioneel is Ook deze onderdelen zijn ontworpen voor reparatie door de klant Als u echter HP verzoekt deze onderdelen voor u te vervangen kunnen daarvoor extra kosten in rekening worden gebracht afhankelijk van het type garantieservice voor het product 3 No Nee Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door...

Страница 18: ...Illustrated parts catalog 18 ...

Страница 19: ...and alcohol pad a 3 00 GHz Intel Xeon processor 5050 dual core 4 MB cache 667 MHz FSB 409423 001 Optional2 b 3 20 GHz Intel Xeon processor 5060 dual core 4 MB cache 1066 MHz FSB 409424 001 Optional2 c 3 73 GHz Intel Xeon processor 5080 dual core 4 MB cache 1066 MHz FSB 412955 001 Optional2 d Dual Core Intel Xeon Processor 5110 1 60 GHz 1066 MHz FSB 1x4 MB L2 cache 416795 001 Optional2 e Dual Core ...

Страница 20: ...s 17 CD ROM drive IDE 48X 397931 001 Optional2 18 CD RW DVD ROM drive IDE 48X 399404 001 Optional2 Memory 19 FBDIMM registered DDR2 a 512 GB 416470 001 Optional2 b 1 GB 416471 001 Optional2 c 2 GB 416472 001 Optional2 Miscellaneous 20 Power switch board with cable 413988 001 Optional2 21 Air baffle 413979 001 Optional2 Cables 22 CD ROM drive signal cable kit 413987 001 Optional2 23 AC power cable ...

Страница 21: ...evono essere necessariamente riparate dal cliente Se il cliente ne affida la riparazione ad HP deve sostenere le spese di spedizione e di manodopera per il servizio 2 Optional Opzionali Parti la cui riparazione da parte del cliente è facoltativa Si tratta comunque di componenti progettati per questo scopo Se tuttavia il cliente ne richiede la sostituzione ad HP potrebbe dover sostenere spese addiz...

Страница 22: ...ieservice voor het product 3 No Nee Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant In verband met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met Nee 1 Mandatory Obrigatória Peças cujo reparo feito pelo cliente é obrigatório Se desejar que a HP ...

Страница 23: ...A and SAS hard drives 33 Air baffle 33 System fans 34 Expansion slot cover 35 Expansion board 36 Media bay blank 37 Half height or full height media device 38 Heatsink 39 Processor 41 PPM 46 FBDIMM 47 Parallel and second serial connector 48 Battery 49 System board 50 Power supply backplane 51 Required tools You need the following items for some procedures T 15 Torx screwdriver Flathead screwdriver...

Страница 24: ...c shock hazards Refer all servicing to qualified personnel WARNING To reduce the risk of injury from electric shock hazards do not open this enclosure Refer all maintenance upgrades and servicing to qualified personnel This symbol indicates the presence of electric shock hazards The area contains no user or field serviceable parts Do not open for any reason WARNING To reduce the risk of injury fro...

Страница 25: ...wn the ramp from the pallet Always handle the rack from both sides WARNING To reduce the risk of personal injury or damage to the equipment adequately stabilize the rack before extending a component outside the rack Extend only one component at a time A rack may become unstable if more than one component is extended WARNING When installing a server in a telco rack be sure that the rack frame is ad...

Страница 26: ...on to place the server in standby mode When the server activates standby power mode the system power LED changes to amber 5 If the server is installed in a rack locate the server by identifying the illuminated rear UID LED button 6 Disconnect the power cords CAUTION Due to the high capacitance in the power supply always wait 30 seconds after disconnecting the power cord before removing the access ...

Страница 27: ...rty rack 1 Power down the server on page 26 2 Extend the server from the rack on page 26 3 Disconnect the cabling and remove the server from the rack Reverse the server installation steps in the documentation that ships with the rack mounting option 4 Remove the server from the rack on page 27 5 Place the server on a sturdy level surface Front bezel This server has a removable bezel that must be u...

Страница 28: ...l before placing the server on its side For operations involving removable media bay access the media bay panel can be removed from the bezel Tower foot To remove the component 1 Power down the server on page 26 2 Remove the tower bezel Front bezel on page 27 3 Place the server on its side ...

Страница 29: ...a T 15 Torx screwdriver to unlock the latch 4 Slide the access panel back about 1 5 cm 0 5 in 5 Lift and remove the access panel NOTE Turn the access panel over to locate the hood labels These labels provide information on installing various options flexible memory configurations LED status indicators and switch settings To replace the component reverse the removal procedure Rack bezel To remove t...

Страница 30: ...applies to rack servers only To remove the component 1 Power down the server on page 26 2 Remove the server from the rack on page 27 3 Use a flat head screwdriver to lift the spring tab 4 Slide the rail forward and remove it from the server 5 Repeat the steps above to remove the other rail To replace the component reverse the removal procedure ...

Страница 31: ...e risk of electric shock do not disassemble the power supply or attempt to repair it Replace it only with the specified spare part CAUTION Do not attempt to remove and replace a power supply as a hot plug procedure unless both bays are populated with power supplies To remove the component 1 Disconnect the power cord from the AC source 2 Disconnect the power cord from the power supply ...

Страница 32: ...lank To replace the component reverse the removal procedure Hard drive blanks To remove the component 1 Open or remove the tower bezel Front bezel on page 27 2 Remove the blank CAUTION To prevent improper cooling and thermal damage do not operate the server unless all bays are populated with either a component or a blank NOTE Depending on model purchased the server may look slightly different than...

Страница 33: ...or a blank 1 Determine the status of the hard drive from the hot plug hard drive LEDs SAS and SATA hard drive LEDs on page 68 2 Back up all server data on the hard drive 3 Remove the hard drive To replace the component reverse the removal procedure Air baffle To remove the component 1 Power down the server on page 26 2 Do one of the following Unlock and remove the bezel Front bezel on page 27 Exte...

Страница 34: ...lth LED When a fan failure occurs the internal health LED illuminates red in non redundant mode and amber in redundant mode To remove the component 1 Power down the server on page 26 2 Do one of the following Unlock and remove the bezel Front bezel on page 27 Extend the server from the rack on page 26 3 Remove the access panel Access panel on page 29 4 Remove the air baffle Air baffle on page 33 5...

Страница 35: ...ocedure Expansion slot cover To remove the component 1 Do one of the following Unlock and remove the bezel Front bezel on page 27 Extend the server from the rack on page 26 2 Remove the access panel Access panel on page 29 3 Push the release latches on the expansion board retainer and open the retainer ...

Страница 36: ... procedure Expansion board CAUTION To prevent damage to the server or expansion boards power down the server and remove all AC power cords before removing or installing the expansion boards To remove the component 1 Power down the server on page 26 2 Do one of the following Unlock and remove the bezel Front bezel on page 27 Extend the server from the rack on page 26 3 Remove the access panel Acces...

Страница 37: ...xpansion board retainer and open the retainer 6 Remove the expansion board To replace the component reverse the removal procedure Media bay blank To remove the component 1 Open or remove the tower bezel Front bezel on page 27 2 Remove the access panel Access panel on page 29 ...

Страница 38: ...eight or full height media device To remove the component 1 Power down the server on page 26 2 Do one of the following Unlock and remove the bezel Front bezel on page 27 Extend the server from the rack on page 26 3 Remove the access panel Access panel on page 29 4 Disconnect data and power cables 5 Remove the device Half height ...

Страница 39: ...wer down the server on page 26 2 Do one of the following Unlock and remove the bezel Front bezel on page 27 Extend the server from the rack on page 26 3 Remove the access panel Access panel on page 29 4 Disconnect the heatsink fan cable from the system board System board LEDs on page 66 5 Open the heatsink locking levers 6 Remove the heatsink ...

Страница 40: ...edures 40 To replace the component 1 Use the alcohol swab to remove all the existing thermal grease from the processor Allow the alcohol to evaporate before continuing 2 Remove the heatsink protective cover 3 Install the heatsink ...

Страница 41: ...revent possible server malfunction do not mix processors of different speeds or cache sizes Refer to the label on the processor heatsink for a description of the processor IMPORTANT Processor socket 1 must be populated at all times or the server does not function CAUTION Removal of the processor or heatsink renders the thermal layer between the processor and heatsink useless Clean the component wi...

Страница 42: ... 42 5 Open the processor retaining latch and the processor socket retaining bracket 6 Using your fingers remove the failed processor To replace the component IMPORTANT Be sure the processor remains inside the processor installation tool ...

Страница 43: ...essor in the tool 2 Align the processor installation tool with the socket and install the spare processor CAUTION The processor is designed to fit one way into the socket Use the alignment guides on the processor and socket to properly align the processor with the socket Refer to the server hood label for specific instructions ...

Страница 44: ...tool clicks and separates from the processor and then remove the processor installation tool 4 Close the processor retaining latch and the processor socket retaining bracket 5 Clean the old thermal grease from the heatsink with the alcohol swab Allow the alcohol to evaporate before continuing ...

Страница 45: ...Removal and replacement procedures 45 6 Apply all the grease to the top of the processor in one of the following patterns to ensure even distribution 7 Install the heatsink ...

Страница 46: ...ne of the following Close or install the tower bezel as needed Slide the server back into the rack 12 Power up the server PPM NOTE PPM 1 is embedded into the system board To remove the component 1 Power down the server on page 26 2 Do one of the following Unlock and remove the bezel Front bezel on page 27 Extend the server from the rack on page 26 3 Remove the access panel Access panel on page 29 ...

Страница 47: ...omponent reverse the removal procedure FBDIMM To remove the component 1 Power down the server on page 26 2 Do one of the following Unlock and remove the bezel Front bezel on page 27 Extend the server from the rack on page 26 3 Remove the access panel Access panel on page 29 4 Remove the air baffle Air baffle on page 33 ...

Страница 48: ...dure Parallel and second serial connector To remove the component 1 Power down the server on page 26 2 Do one of the following Unlock and remove the bezel Front bezel on page 27 Extend the server from the rack on page 26 3 Remove the access panel Access panel on page 29 4 Push the release latches on the expansion board retainer and open the retainer ...

Страница 49: ...xide or an alkaline battery pack A risk of fire and burns exists if the battery pack is not properly handled To reduce the risk of personal injury Do not attempt to recharge the battery Do not expose the battery to temperatures higher than 60 C 140 F Do not disassemble crush puncture short external contacts or dispose of in fire or water Replace only with the spare designated for this product To r...

Страница 50: ...ack on page 26 3 Remove the access panel Access panel on page 29 4 Remove the air baffle Air baffle on page 33 5 Remove the system fans on page 34 6 Remove all expansion boards Expansion board on page 36 7 Remove all FBDIMMs FBDIMM on page 47 8 Remove the PPM PPM on page 46 9 Remove the heatsink on page 39 10 Remove the processor Processor on page 41 CAUTION To avoid damage to the system board Do ...

Страница 51: ...9 key to access RBSU 2 Select the System Options menu 3 Select Serial Number The following warning is displayed WARNING WARNING WARNING The serial number is loaded into the system during the manufacturing process and should NOT be modified This option should only be used by qualified service personnel This value should always match the serial number sticker located on the chassis 4 Press the Enter...

Страница 52: ...move the air baffle Air baffle on page 33 6 Remove the system fans on page 34 7 Remove all expansion boards Expansion board on page 36 NOTE Removing the processors PPM FBDIMMs and cache module from the system board is not necessary for this procedure 8 Remove the system board System board on page 50 9 Disconnect the cables from the power supply backplane 10 Remove the power supply backplane To rep...

Страница 53: ...hp com wwpc pscmisc vac us en ss proliant proliant ml html Standard SATA cabling Item Description 1 SATA cable drives 1 4 2 SATA cable drives 5 8 Optional ATA or ATAPI device cabling This server includes one IDE cable the Cable Select Cable that can connect up to two ATA or ATAPI devices to the system through the integrated IDE controller This cable has three clearly labeled connectors If only one...

Страница 54: ...PORTANT If the network operating system is Novell NetWare HP recommends that you connect the CD ROM to the primary IDE channel and to the Drive 0 connector on the IDE cable NOTE ATA IDE hard drives are not supported ...

Страница 55: ...ebsite http www hp com support Navigate to the server technical support page Under self help resources select ProLiant Troubleshooting Guide The Technical Documentation website http www docs hp com Select Enterprise Servers Workstations and Systems Hardware and then the appropriate server Automatic Server Recovery ASR is a feature that causes the system to restart when a catastrophic operating sys...

Страница 56: ...rom within HP Insight Diagnostics on page 58 For more information refer to the Management CD in the HP ProLiant Essentials Foundation Pack HP Instant Support Enterprise Edition ISEE is a proactive remote monitoring and diagnostic tool to help manage your systems and devices a feature of HP support ISEE provides continuous hardware event monitoring and automated notification to identify and prevent...

Страница 57: ...Based Setup Utility RBSU an embedded configuration utility performs a wide range of configuration activities that may include Configuring system devices and installed options Displaying system information Selecting the primary boot controller For more information on RBSU refer to the HP ROM Based Setup Utility User Guide on the Documentation CD or the HP website http www hp com servers smartstart ...

Страница 58: ...ftware SmartStart is a collection of software that optimizes single server setup providing a simple and consistent way to deploy server configuration SmartStart has been tested on many ProLiant server products resulting in proven reliable configurations SmartStart assists the deployment process by performing a wide range of configuration activities including Configuring hardware using embedded con...

Страница 59: ...artStart CD HP Insight Diagnostics Online Edition is a web based application that captures system configuration and other related data needed for effective server management Available in Microsoft Windows and Linux versions the utility helps to ensure proper system operation For more information or to download the utility refer to the HP website http www hp com servers diags ...

Страница 60: ...s 63 System board components 64 System board LEDs 66 System LEDs and internal health LED combinations 67 SAS and SATA hard drive LEDs 68 SAS and SATA hard drive LED combinations 68 Front panel components Item Description 1 Removable media bays 4 2 CD ROM drive 3 Hot plug hard drive bays 8 bay drive cage model 4 Hot plug hard drive bays 6 bay drive cage model 5 USB connectors 2 ...

Страница 61: ...stem board LEDs on page 66 Red System critical To identify the component in a critical state refer to system board LEDs on page 66 Off Normal when in standby mode 4 External health LED power supply Green Normal Amber Power redundancy failure Red Critical power supply failure 5 NIC 1 activity LED Green Network link Flashing Network link and activity Off No link to network If power is off view statu...

Страница 62: ...l connector 3 USB connectors 2 4 RJ 45 Ethernet connector iLO 2 management 5 RJ 45 Ethernet connector data 6 PCI Express x8 slots x4 routed 7 PCI X slots 100 MHz 8 PCI X slot 133 MHz 9 Optional redundant hot plug power supply bay 10 Mouse connector 11 Keyboard connector 12 Power cord connector ...

Страница 63: ...LED and button Blue Activated Flashing blue Remote inquiry Off Deactivated 3 iLO 2 activity LED Green or flashing Network activity Off No network activity 4 iLO 2 link LED Green Linked to network Off Not linked to network 5 10 100 1000 NIC activity LED Green or flashing Network activity Off No network activity 6 10 100 1000 NIC link LED Green Linked to network Off Not linked to network ...

Страница 64: ...or 8 Diskette drive connector 9 SAS SATA connector drives 1 4 10 SAS SATA connector drives 5 8 11 PPM slot 12 HP Smart Array E200i memory connector 13 Serial port connector 14 NMI jumper 15 Optional parallel port connector 16 System battery 17 System maintenance switch 18 PCI X slot 1 133 MHz 19 PCI X slots 2 3 100 MHz 20 PCI Express x8 slots 4 6 x4 routed 21 Optional redundant system fan 4 connec...

Страница 65: ...ends that system administrators perform an NMI event by pressing a dump switch The NMI event enables a hung system to become responsive again System maintenance switch Position Default Function S1 iLO 2 security Off iLO 2 security is enabled On iLO 2 security is disabled S2 Off Off System configuration can be changed On System configuration is locked S3 Off Reserved S4 Off Reserved S5 Off Off Powe...

Страница 66: ...ing 6 AC power Green Power supply is on and functioning Off No AC power or failed power supply 7 Processor 2 fan failure fan 6 Amber Fan is not installed or has failed Off Processor fan is functioning 8 PPM 2 Amber PPM 2 failed Off PPM 2 functioning 9 Temperature threshold Amber System temperature threshold exceeded Off Normal operation 10 Optional redundant system fan 4 Amber Redundant fan has fa...

Страница 67: ...amber Red One or more of the following conditions may exist Processor in socket X has failed Processor in socket X failed over to the second processor Processor X is not installed in the socket Processor X is not supported Processor heatsink is not attached properly Amber Processor in socket X is in a pre failure condition Processor failure both sockets amber Red Processor types are mismatched PPM...

Страница 68: ... a management application On off or flashing Steadily blue The drive is operating normally and it has been selected by a management application On Amber flashing regularly 1 Hz A predictive failure alert has been received for this drive Replace the drive as soon as possible On Off The drive is online but it is not active currently Flashing regularly 1 Hz Amber flashing regularly 1 Hz Do not remove...

Страница 69: ...rly 1 Hz The drive is active but a predictive failure alert has been received for this drive Replace the drive as soon as possible Flashing irregularly Off The drive is active and it is operating normally Off Steadily amber A critical fault condition has been identified for this drive and the controller has placed it offline Replace the drive as soon as possible Off Amber flashing regularly 1 Hz A...

Страница 70: ...on operating 5 to 95 All temperature ratings shown are for sea level An altitude derating of 1 C per 300 m 1 8 F per 1 000 ft to 3048 m 10 000 ft is applicable No direct sunlight allowed Storage maximum humidity of 95 is based on a maximum temperature of 45 C 113 F Altitude maximum for storage corresponds to a pressure minimum of 70 KPa Server specifications Specification Value Dimension Height wi...

Страница 71: ... lb Input requirements Rated input voltage 100 VAC to 240 VAC Rated input frequency 47 Hz to 63 Hz Rated input current 10 A 110 V to 5 A 220 V Rated input power 1500 W BTUs per hour 2730 Power supply output Rated steady state power 800 W low line 1000 W high line Maximum peak power 1000 w low line 1200 W high line Hot plug power supply calculations For hot plug power supply specifications and calc...

Страница 72: ...ations CAUTION Be sure to install FBDIMMs in the proper configuration Refer to the Documentation CD Item Description Type Registered DDR2 Fully Buffered DIMMs FBDIMMs Size 512 MB 1 GB 2 GB Width 72 bits Upgrade requirement FBDIMMs must be installed in pairs within a bank except in single FBDIMM mode which supports a single 512 MB FBDIMM installed in slot 1A A bank must be populated with 2 FBDIMMs ...

Страница 73: ...0 KB s sustained 1X 1500 3600 KB s 10X to 24X Burst 16 6 MB s Access times typical Full stroke 300 ms Random 140 ms Diameter 12 cm 8 cm 4 70 in 3 15 in Thickness 1 2 mm 0 05 in Track pitch 1 6 µm 6 3 10 7 in Cache buffer 128 KB Startup time 10 s Stop time 5 s single 30 s multisession Laser parameters Type Semiconductor laser GaAs Wave length 700 25 nm Divergence angle 53 5 1 5 Output power 0 14 mW...

Страница 74: ...ced Technology Attachment ATAPI Advanced Technology Attachment Packet Interface BIOS Basic Input Output System DDR double data rate FBDIMM fully buffered DIMM IDE integrated device electronics iLO 2 Integrated Lights Out 2 IML Integrated Management Log ISEE Instant Support Enterprise Edition LED light emitting diode ...

Страница 75: ...ation for Arrays PCI Express peripheral component interconnect express PCI X peripheral component interconnect extended PPM processor power module RAID redundant array of inexpensive or independent disks RBSU ROM Based Setup Utility RDP Rapid Deployment Pack ROM read only memory SAS serial attached SCSI SATA serial ATA SFF small form factor ...

Страница 76: ...Acronyms and abbreviations 76 SIM Systems Insight Manager UID unit identification USB universal serial bus ...

Страница 77: ...tal specifications 70 expansion board 36 expansion slot covers 35 extending server from rack 26 external health LED 60 61 F fans 34 FBDIMM slot locations 64 FBDIMMs 47 64 65 66 72 features 60 flash ROM 57 front bezel 27 29 front panel components 60 front panel LEDs 61 full height media drive 38 H half height media drive 35 hard drive blanks 32 hard drive LEDs 68 hard drives 33 68 hard drives deter...

Страница 78: ...components 62 rear panel components 62 removal and replacement procedures 23 required tools 23 ROM updating 58 ROMPaq utility 57 S safety considerations 23 SAS cabling 53 SAS hard drive 33 SAS hard drive LEDs 68 SATA cabling 53 serial connector 48 62 server rails removing 30 server specifications 70 71 SmartStart autorun menu 58 SmartStart overview 58 specifications 70 71 72 specifications environ...

Отзывы: