HP LTO Ultrium 4 drives technical reference manual, volume 5: UNIX, Linux and OpenVMS configuration guide
31
7
Sun (Solaris 8, 9, 10) servers and workstations
Fibre Channel drives
Before configuring your system to support an HP LTO Ultrium drive, ensure that the drive is visible to
the Sun system HBA by correctly zoning the fabric switch (if one is being used).
Configuring the device files
Before configuring FC-attached drives, ensure the operating system is updated with the latest
recommended patches. On Solaris 8 and 9 you also need to install the Sun/StorageTek StorEdge
SAN Foundation software from
www.sun.com/download
(select the Storage Management link, then
StorageTek SAN x.x
).
When SAN configuration is complete, verify that the drive is visible to the HBA by typing:
% cfgad m -al
This should produce an output similar to:
...
c3::500 60b000
xxxxxxx
tape connecte d conf igured unknown
...
This indicates that the drive is configured and the device files built. In this example
c3::50060b000
xxxxxxx
is the attachment point identifier with
50060b000
xxxxxxx
being
the WWN of the drive port attached to the SAN and visible to the HBA.
If you do
not
see anything similar to the example above, recheck the SAN connections and the
zoning configuration to ensure that the HBA and drive ports are visible to each other.
If the tape device shows as
unconfigured
, type the following:
% cfgad m -c con figure c3 ::50060b0 00
xxxxxxx
This will build the necessary device file in the
/dev/rmt
directory.
To verify the particular devices associated with a specific WWN then use the following command.
% ls -a l /dev/r mt | grep 50060b00 0
xxxxxxx
Replace
50060b000
xxxxxxx
with the appropriate WWN for the drive.
SCSI drives
Determining the SCSI ID
Before you configure your system to support an HP LTO Ultrium drive, determine which SCSI ID to
use. IDs must be unique for each device on attached to the SCSI bus.
1.
Use the
modinfo
command to identify SCSI controller drivers installed on the system:
# m odin fo | gre p "HBA Dr iver"
Содержание LTO-4 Ultrium 1760
Страница 10: ...Introduction 8 ...
Страница 20: ...HP HP UX servers and workstations 18 ...
Страница 22: ...HP OpenVMS servers and workstations 20 ...
Страница 24: ...HP Tru64 5 1x servers and workstations 22 ...
Страница 28: ...Linux kernel 2 6 x servers and workstations 26 ...
Страница 38: ...Sun Solaris 8 9 10 servers and workstations 36 ...
Страница 42: ...Verifying the installation 40 ...
Страница 46: ...44 V verifying installation 37 W wide data transfer 41 ...